Literature DB >> 11950645

Relationship between findings of conventional and contrast-enhanced transcranial color-coded real-time sonography and angiography in patients with basilar artery occlusion.

Masatoshi Koga1, Kazumi Kimura, Kazuo Minematsu, Takenori Yamaguchi.   

Abstract

BACKGROUND AND
PURPOSE: Contrast-enhanced transcranial color-coded real-time sonography (TCCS) is a promising tool for the evaluation of brain circulation. The purpose of the present study was to assess the diagnostic ability of conventional and contrast-enhanced TCCS in patients with acute stroke and basilar artery occlusion and to compare the findings with those of angiography.
METHODS: We prospectively performed conventional and contrast-enhanced TCCS within 3 days before or after digital subtraction angiography or MR angiography in 62 consecutive patients with acute ischemic stroke. We assigned the patients to two groups on the basis of angiographic findings: basilar artery occlusion group (n = 7) and control group without basilar artery occlusion (n = 55). We obtained basilar artery flow images showing the direction of blood flow using TCCS through a suboccipital window.
RESULTS: In the control group, the detection rate of basilar artery flow using conventional and contrast-enhanced TCCS was 76.4% and 98.2%, respectively (P <.001), and the flow direction was antegrade in all patients. In the basilar artery occlusion group, neither conventional nor contrast-enhanced TCCS could obtain flow images of the proximal basilar artery in any patient. In five patients with proximal basilar artery occlusion, a reversed flow image in the distal basilar artery obtained by contrast-enhanced TCCS was confirmed by angiography to be blood supply through collateral circulation from the carotid systems. However, two patients with distal basilar artery occlusion did not have this sign.
CONCLUSION: Contrast-enhanced TCCS is more sensitive in imaging basilar artery flow than is conventional TCCS. When examined with contrast-enhanced TCCS, a combination of absent basilar artery flow and the reversed basilar artery flow sign may be a diagnostic indicator of basilar artery occlusion.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11950645      PMCID: PMC7975105     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  17 in total

1.  Evaluation of posterior cerebral artery flow velocity by transcranial color-coded real-time sonography.

Authors:  K Kimura; K Minematsu; M Yasaka; K Wada; T Yamaguchi
Journal:  Ultrasound Med Biol       Date:  2000-02       Impact factor: 2.998

2.  Contrast-enhanced transcranial color-coded duplex sonography: efficiency and validity.

Authors:  T Gerriets; G Seidel; I Fiss; B Modrau; M Kaps
Journal:  Neurology       Date:  1999-04-12       Impact factor: 9.910

3.  Transcranial color-coded real-time sonography in adults.

Authors:  U Bogdahn; G Becker; J Winkler; K Greiner; J Perez; B Meurers
Journal:  Stroke       Date:  1990-12       Impact factor: 7.914

4.  Imaging of the basal cerebral arteries and measurement of blood velocity in adults by using transcranial real-time color flow Doppler sonography.

Authors:  T Tsuchiya; M Yasaka; T Yamaguchi; K Kimura; T Omae
Journal:  AJNR Am J Neuroradiol       Date:  1991 May-Jun       Impact factor: 3.825

5.  Diagnosis and monitoring of middle cerebral artery occlusion with contrast-enhanced transcranial color-coded real-time sonography in patients with inadequate acoustic bone windows.

Authors:  T Postert; B Braun; J Federlein; H Przuntek; O Köster; T Büttner
Journal:  Ultrasound Med Biol       Date:  1998-03       Impact factor: 2.998

Review 6.  Echo-enhanced ultrasound for diagnosis and management in stroke patients.

Authors:  E B Ringelstein
Journal:  Eur J Ultrasound       Date:  1998-07

7.  Transcranial color-coded duplex sonography in the evaluation of collateral flow through the circle of Willis.

Authors:  R W Baumgartner; I Baumgartner; H P Mattle; G Schroth
Journal:  AJNR Am J Neuroradiol       Date:  1997-01       Impact factor: 3.825

8.  Insufficient and absent acoustic temporal bone window: potential and limitations of transcranial contrast-enhanced color-coded sonography and contrast-enhanced power-based sonography.

Authors:  T Postert; J Federlein; H Przuntek; T Büttner
Journal:  Ultrasound Med Biol       Date:  1997       Impact factor: 2.998

9.  Contrast-enhanced transcranial imaging. Results of an American phase-two study.

Authors:  S Otis; M Rush; R Boyajian
Journal:  Stroke       Date:  1995-02       Impact factor: 7.914

10.  Potential and limitations of transcranial color-coded sonography in stroke patients.

Authors:  G Seidel; M Kaps; T Gerriets
Journal:  Stroke       Date:  1995-11       Impact factor: 7.914

View more
  3 in total

Review 1.  [Imaging techniques in diagnosis of brainstem infarction].

Authors:  G Schulte-Altedorneburg; H Brückmann
Journal:  Nervenarzt       Date:  2006-06       Impact factor: 1.214

2.  Transcatheter coil embolization for large pulmonary arteriovenous fistulae through an artificial tricuspid ball valve.

Authors:  Sei Matsuo; Kazuyuki Ozaki; Yuji Matsuo; Toshiki Takano; Tohru Watanabe; Tatsuhiko Sato; Takuya Yagi; Tsugumi Takayama; Makoto Hoyano; Takao Yanagawa; Takuya Ozawa; Yosuke Horii; Tohru Takano; Takeshi Kashimura; Tohru Minamino
Journal:  J Cardiol Cases       Date:  2021-06-24

3.  Different Imaging Strategies in Patients With Possible Basilar Artery Occlusion: Cost-Effectiveness Analysis.

Authors:  Sebastian E Beyer; Myriam G Hunink; Florian Schöberl; Louisa von Baumgarten; Steffen E Petersen; Martin Dichgans; Hendrik Janssen; Birgit Ertl-Wagner; Maximilian F Reiser; Wieland H Sommer
Journal:  Stroke       Date:  2015-05-28       Impact factor: 7.914

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.