Literature DB >> 11948900

Endovascular stent implantation in the pulmonary arteries of infants and children without the use of a long vascular sheath.

Robert H Pass1, Daphne T Hsu, Carl P Garabedian, Myles S Schiller, K Anitha Jayakumar, William E Hellenbrand.   

Abstract

Endovascular stent implantation for pulmonary artery stenosis requires the use of a long, large-bore vascular sheath to insure precise implantation without embolization or malposition. A long vascular sheath may be difficult to position and usage may be associated with vascular compromise and/or hemodynamic embarrassment, especially in infants and small children. We report a new technique for pulmonary artery endovascular stent implantation without the use of a long sheath. From December 2000 to May 2001, 10 patients underwent implantation of 13 Palmaz Corinthian premounted biliary transhepatic stents for pulmonary artery stenosis. Median age was 0.8 years (range, 0.5-18.5) and median weight was 11.8 kg (range, 4.6-65). Patient diagnoses were tetralogy of Fallot (five), double outlet right ventricle (three), branch peripheral pulmonary artery stenosis (two), single ventricle s/p cavopulmonary shunt (one), and truncus arteriosus (one). All Palmaz Corinthian stents were delivered uncovered on Cordis Opta LP balloon catheters via short sheaths (6-7 Fr); super-stiff guidewires were not always necessary. These stents, with a maximal expanded diameter of 12 mm, were placed for peripheral pulmonary artery stenosis as a definitive procedure or at the pulmonary artery bifurcation in patients who were expected to undergo future open heart surgery. The stents were initially implanted on 4, 6, or 8 mm balloon catheters and further expanded if needed. Stents were placed in the right pulmonary artery alone in three patients, left pulmonary artery alone in four patients, and side-by-side stents were implanted simultaneously in three patients. All thirteen stents were implanted successfully in the desired location without stent malposition or embolization. Mean angiographic diameter increased from 2.5 +/- 1.5 to 5.7 +/- 1.4 mm (P < 0.01) and peak systolic ejection gradients decreased from 44 +/- 22 to 14 +/- 11.6 mm Hg (P < 0.01). The uncovered delivery of the premounted Palmaz Corinthian stent allowed for precise and safe endovascular stent implantation without the hemodynamic and technical problems associated with long vascular sheath usage. This technique is useful for the palliation of proximal pulmonary artery stenosis and is effective definitive treatment for peripheral pulmonary artery stenosis in small infants and children. Copyright 2002 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2002        PMID: 11948900     DOI: 10.1002/ccd.10160

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  8 in total

1.  Vessel restenosis versus "streamlining".

Authors:  C E Mullins
Journal:  Heart       Date:  2002-11       Impact factor: 5.994

2.  Fontan "Ten Commandments" revisited and revised.

Authors:  Herbert J Stern
Journal:  Pediatr Cardiol       Date:  2010-10-20       Impact factor: 1.655

3.  Cheatham-Platinum stent implantation for pulmonary artery stenosis in children and adolescents: immediate and mid-term outcome.

Authors:  Wu Zhao; Fen Li; Ai-Qing Zhou; Wei Gao; Zhi-Qing Yu; Kun Sun; Mei-Rong Huang; Yun Li; Jian-Ping Yang
Journal:  World J Pediatr       Date:  2010-11-16       Impact factor: 2.764

4.  Successful dilatation of left pulmonary artery stenosis by stent implantation through a modified Blalock-Taussig shunt in an infant with pulmonary atresia and ventricular septal defect.

Authors:  T Tanaka; A Kawakita; I Shiraishi; M Yamagishi; T Itoi; K Hamaoka
Journal:  Pediatr Cardiol       Date:  2005 Sep-Oct       Impact factor: 1.655

5.  Medium and long-term outcomes after bilateral pulmonary artery stenting in children and adults with congenital heart disease.

Authors:  Ismael Gonzalez; Damien Kenny; Shari Slyder; Ziyad M Hijazi
Journal:  Pediatr Cardiol       Date:  2012-07-28       Impact factor: 1.655

6.  Stent implantation and balloon angioplasty for treatment of branch pulmonary artery stenosis in children.

Authors:  Lorenz Baerlocher; Oliver Kretschmar; Paul Harpes; Urs Arbenz; Felix Berger; Walter Knirsch
Journal:  Clin Res Cardiol       Date:  2007-12-28       Impact factor: 5.460

7.  Interventions complementing surgery as part of multistage treatment for hypoplastic left heart syndrome: one center's experience.

Authors:  T Moszura; A Mazurek-Kula; P Dryzek; J J Moll; J A Moll; A Sysa; S A Qureshi
Journal:  Pediatr Cardiol       Date:  2008-08-26       Impact factor: 1.655

8.  Preliminary testing and evaluation of the renata minima stent, an infant stent capable of achieving adult dimensions.

Authors:  Evan M Zahn; Eason Abbott; Neil Tailor; Shyam Sathanandam; Dustin Armer
Journal:  Catheter Cardiovasc Interv       Date:  2021-05-04       Impact factor: 2.585

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.