Literature DB >> 11948849

Effects of liquid chromatography mobile phase buffer contents on the ionization and fragmentation of analytes in liquid chromatographic/ionspray tandem mass spectrometric determination.

Jamie J Zhao1, Amy Y Yang, J Douglas Rogers.   

Abstract

The effects of liquid chromatography mobile phase buffer contents on the ionization and fragmentation of drug molecules in liquid chromatographic/ionspray tandem mass spectrometric (LC/MS/MS) determination were evaluated for simvastatin (SV) and its hydroxy acid (SVA). The objective was to improve further the sensitivity for SV by overcoming the unfavorable condition caused by the formation of multiple major adduct ions and multiple major fragment ions when using ammonium as LC mobile phase buffer. Mobile phases (70:30 acetonitrile-buffer, 2 mM, pH 4.5) with buffers made from ammonium, hydrazine or alkyl (methyl, ethyl, dimethyl or trimethyl)-substituted ammonium acetate were evaluated. Q1 scan and product ion scan spectra were obtained for SV in each of the mobile phases under optimized conditions. The results showed that, with the alkylammonium buffers, the alkylammonium-adducted SV was observed as the only major molecular ion, while the formation of other adduct ions ([M + H](+), [M + Na](+) and [M + K](+)) was successfully suppressed. On the other hand, product ion spectra with a single major fragment ion were not observed for any of the alkylammonium-adducted SVs. The affinity of the alkylammoniums to SV and the basicity of the alkylamines are believed to be factors influencing the formation and abundance of molecular and fragment ions, respectively. Methylammonium acetate provided the most favorable condition among all the buffers evaluated and improved the sensitivity several-fold for SV in LC/MS/MS quantitation compared with that obtained using ammonium acetate buffer. Better precision for SV in both Q1 and SRM scans was observed when using methylammonium buffer compared with those using ammonium buffer. The mobile phase buffer contents did not seem to affect the ionization, fragmentation and chromatography of SVA. The results of this evaluation can be applied to similar situations with other organic molecules in ionspray LC/MS/MS determination. Copyright 2002 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11948849     DOI: 10.1002/jms.299

Source DB:  PubMed          Journal:  J Mass Spectrom        ISSN: 1076-5174            Impact factor:   1.982


  4 in total

1.  Adduct Formation in ESI/MS by Mobile Phase Additives.

Authors:  Anneli Kruve; Karl Kaupmees
Journal:  J Am Soc Mass Spectrom       Date:  2017-03-15       Impact factor: 3.109

2.  An improved method for measuring metaldehyde in surface water using liquid chromatography tandem mass spectrometry.

Authors:  Melanie Schumacher; Glenn Castle; Anthony Gravell; Graham A Mills; Gary R Fones
Journal:  MethodsX       Date:  2016-03-10

3.  Comparison of conventional and supported liquid extraction methods for the determination of sitagliptin and simvastatin in rat plasma by LC-ESI-MS/MS.

Authors:  B Ramesh; N Manjula; S R Bijargi; V U M Sarma; P Sita Devi
Journal:  J Pharm Anal       Date:  2014-12-02

4.  Comparative pharmacokinetics and safety assessment of transdermal berberine and dihydroberberine.

Authors:  Beth Buchanan; Qingfang Meng; Mathieu-Marc Poulin; Jonathan Zuccolo; Chike Godwin Azike; Joseph Gabriele; David Charles Baranowski
Journal:  PLoS One       Date:  2018-03-26       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.