Automatic tuned MRI RF coil for multinuclear imaging of small animals at 3T.

L Tugan Muftuler1, Gultekin Gulsen, Kumsal D Sezen, Orhan Nalcioglu.   

Abstract

We have developed an MRI RF coil whose tuning can be adjusted automatically between 120 and 128 MHz for sequential spectroscopic imaging of hydrogen and fluorine nuclei at field strength 3 T. Variable capacitance (varactor) diodes were placed on each rung of an eight-leg low-pass birdcage coil to change the tuning frequency of the coil. The diode junction capacitance can be controlled by the amount of applied reverse bias voltage. Impedance matching was also done automatically by another pair of varactor diodes to obtain the maximum SNR at each frequency. The same bias voltage was applied to the tuning varactors on all rungs to avoid perturbations in the coil. A network analyzer was used to monitor matching and tuning of the coil. A Pentium PC controlled the analyzer through the GPIB bus. A code written in LABVIEW was used to communicate with the network analyzer and adjust the bias voltages of the varactors via D/A converters. Serially programmed D/A converter devices were used to apply the bias voltages to the varactors. Isolation amplifiers were used together with RF choke inductors to provide isolation between the RF coil and the DC bias lines. We acquired proton and fluorine images sequentially from a multicompartment phantom using the designed coil. Good matching and tuning were obtained at both resonance frequencies. The tuning and matching of the coil were changed from one resonance frequency to the other within 60 s. (c) 2002 Elsevier Science (USA).

Entities:  

Mesh:

Year:  2002        PMID: 11945031     DOI: 10.1006/jmre.2002.2510

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  6 in total

1.  Design of an Electrically Automated RF Transceiver Head Coil in MRI.

Authors:  Sung-Min Sohn; Lance DelaBarre; Anand Gopinath; John Thomas Vaughan
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2014-10-28       Impact factor: 3.833

2.  Parallel-plate waveguide for volume radio frequency transmission in MRI.

Authors:  Hai Lu; Shuo Shang; Shumin Wang
Journal:  Magn Reson Med       Date:  2014-11-13       Impact factor: 4.668

3.  Feasibility study of a unilateral RF array coil for MR-scintimammography.

Authors:  Seunghoon Ha; Mark J Hamamura; Werner W Roeck; James Hugg; Douglas J Wagenaar; Dirk Meier; Bradley E Patt; Orhan Nalcioglu
Journal:  Phys Med Biol       Date:  2011-10-05       Impact factor: 3.609

4.  A Review of Non-1H RF Receive Arrays in Magnetic Resonance Imaging and Spectroscopy.

Authors:  Matthew Wilcox; Steven M Wright; Mary McDougall
Journal:  IEEE Open J Eng Med Biol       Date:  2020-10-13

5.  Recent Advances in 19Fluorine Magnetic Resonance Imaging with Perfluorocarbon Emulsions.

Authors:  Anne H Schmieder; Shelton D Caruthers; Jochen Keupp; Samuel A Wickline; Gregory M Lanza
Journal:  Engineering (Beijing)       Date:  2016-03-16       Impact factor: 7.553

6.  A Novel Metamaterial-Inspired RF-coil for Preclinical Dual-Nuclei MRI.

Authors:  Anna Hurshkainen; Anton Nikulin; Elodie Georget; Benoit Larrat; Djamel Berrahou; Ana Luisa Neves; Pierre Sabouroux; Stefan Enoch; Irina Melchakova; Pavel Belov; Stanislav Glybovski; Redha Abdeddaim
Journal:  Sci Rep       Date:  2018-06-15       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.