Literature DB >> 11942865

Accuracy of radial arterial pressure measurement during surgery under controlled hypotension.

A Yazigi1, S Madi-Jebara, F Haddad, G Hayek, D Jawish.   

Abstract

BACKGROUND: Radial arterial pressure underestimates the pressure in the aorta in several clinical situations. A central-to-radial pressure gradient was attributed to intense vasodilation. The aim of this study was to evaluate the accuracy of radial pressure monitoring during controlled hypotension achieved with profound arterial vasodilation.
METHODS: Ten patients with ASA physical status I and II undergoing maxillofacial surgery under general anesthesia were enrolled in this prospective study. Radial and femoral arteries were cannulated and connected to a pressure monitoring system. Controlled hypotension was achieved with an infusion of nicardipine titrated to maintain MAP between 50 and 60 mmHg. Simultaneous radial and femoral systolic, mean and diastolic arterial pressures were recorded before, during and after controlled hypotension. Results were expressed as mean +/- SD. Concomitant radial and femoral pressures were compared by a paired Student's test, P < 0.05 being significant.
RESULTS: In all, 150 sets of arterial pressures measurement were obtained. There were no statistically significant differences between radial and femoral arterial pressures measured before, during or after controlled hypotension.
CONCLUSION: Radial arterial pressure is an accurate measure of central arterial pressure during controlled hypotension achieved with arterial vasodilation.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11942865     DOI: 10.1034/j.1399-6576.2002.460208.x

Source DB:  PubMed          Journal:  Acta Anaesthesiol Scand        ISSN: 0001-5172            Impact factor:   2.105


  6 in total

Review 1.  Arterial Catheterization and Infection: Toll-like Receptors in Defense against Microorganisms and Therapeutic Implications.

Authors:  Zakary J Hambsch; Mitchell J Kerfeld; Daniel R Kirkpatrick; Dan M McEntire; Mark D Reisbig; Charles F Youngblood; Devendra K Agrawal
Journal:  Clin Transl Sci       Date:  2015-08-14       Impact factor: 4.689

2.  Can we trust radial artery pressure monitoring for cardiac surgery?

Authors:  Matthias Jacquet-Lagrèze; Adrian Costescu; André Denault
Journal:  Can J Anaesth       Date:  2022-10-05       Impact factor: 6.713

3.  Peripheral arterial blood pressure versus central crterial blood pressure monitoring in critically ill patients after Cardio-pulmonary Bypass.

Authors:  Rana Altaf Ahmad; Suhail Ahmad; Anjum Naveed; Mirza Ahmad Raza Baig
Journal:  Pak J Med Sci       Date:  2017 Mar-Apr       Impact factor: 1.088

4.  Peripheral arterial blood pressure monitoring adequately tracks central arterial blood pressure in critically ill patients: an observational study.

Authors:  Mariano Alejandro Mignini; Enrique Piacentini; Arnaldo Dubin
Journal:  Crit Care       Date:  2006       Impact factor: 9.097

5.  Central-radial artery pressure gradient after cardiopulmonary bypass is associated with cardiac function and may affect therapeutic direction.

Authors:  Jie Sun; Zhengnian Ding; Yanning Qian; Yong G Peng
Journal:  PLoS One       Date:  2013-07-22       Impact factor: 3.240

6.  Efficacy of minimal invasive cardiac output and ScVO2 monitoring during controlled hypotension for double-jaw surgery.

Authors:  Seokkon Kim; Jaegyok Song; Sungmi Ji; Min A Kwon; Dajeong Nam
Journal:  J Dent Anesth Pain Med       Date:  2019-12-27
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.