Literature DB >> 11936598

Model-based processing scheme for quantitative 4-D cardiac MRI analysis.

George Stalidis1, Nicos Maglaveras, Serafim N Efstratiadis, Athanasios S Dimitriadis, Costas Pappas.   

Abstract

In this paper, we present an integrated model-based processing scheme for cardiac magnetic resonance imaging (MRI), embedded in an interactive computing environment suitable for quantitative cardiac analysis, which provides a set of functions for the extraction, modeling, and visualization of cardiac shape and deformation. The methods apply four-dimensional (4-D) processing (three spatial and one temporal) to multiphase multislice MRI acquisitions and produce a continuous 4-D model of the myocardial surface deformation. The model is used to measure diagnostically useful parameters, such as wall motion, myocardial thicking, and myocardial mass measurements. The proposed model-based shape extraction method has the advantage of integrating local information into an overall representation and produces a robust description of cardiac cavities. A learning segmentation process that incorporates a generating-shrinking neural network is combined with a spatiotemporal parametric modeling method through functional basis decomposition. A multiscale approach is adopted, which uses at each step a coarse-scale model defined at the previous step in order to constrain the boundary detection. The representation accuracy starts from a coarse but smooth estimation of the approximate cardiac shape and is gradually increased to the desired detail. The main advantages of the proposed methods are efficiency, lack of uncertainty about convergence, and robustness to image artifacts. Experimental results obtained from application to clinical multislice multiphase MRI examinations of normal volunteers and patients with medical record of myocardial infarction were satisfactory in terms of accuracy and robustness.

Entities:  

Mesh:

Year:  2002        PMID: 11936598     DOI: 10.1109/4233.992164

Source DB:  PubMed          Journal:  IEEE Trans Inf Technol Biomed        ISSN: 1089-7771


  3 in total

1.  A deep Boltzmann machine-driven level set method for heart motion tracking using cine MRI images.

Authors:  Jian Wu; Thomas R Mazur; Su Ruan; Chunfeng Lian; Nalini Daniel; Hilary Lashmett; Laura Ochoa; Imran Zoberi; Mark A Anastasio; H Michael Gach; Sasa Mutic; Maria Thomas; Hua Li
Journal:  Med Image Anal       Date:  2018-04-06       Impact factor: 8.545

2.  The 4D B-spline method of calculating left ventricular functional parameters of cardiac MRI to evaluate myocardial injury of the apical segment in patients with myocarditis: a case-controlled observational study.

Authors:  Xin-Xiang Zhao; Wei-Feng Yuan
Journal:  Quant Imaging Med Surg       Date:  2020-11

Review 3.  A review of heart chamber segmentation for structural and functional analysis using cardiac magnetic resonance imaging.

Authors:  Peng Peng; Karim Lekadir; Ali Gooya; Ling Shao; Steffen E Petersen; Alejandro F Frangi
Journal:  MAGMA       Date:  2016-01-25       Impact factor: 2.310

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.