Literature DB >> 11935506

Effect of dowel space preparation and composite cement thickness on retention of a prefabricated dowel.

Mark S Hagge1, Ralan D M Wong, James S Lindemuth.   

Abstract

PURPOSE: This investigation examined what effect cement thickness had on retention of prefabricated endodontic dowels luted with a composite resin cement (Panavia 21 OP; J Morita, Irvine, CA) into canals previously obturated with gutta percha and a eugenol-based sealer.
MATERIALS AND METHODS: Sixty-four single-rooted teeth were decoronated, filed, cleaned, and sequentially shaped with sizes 2-5 Gates Glidden drills (Dentsply/Maillefer, Tulsa, OK) and 0.12 taper rotary instrumentation. Teeth were then divided into 4 groups of 16 specimens each. All specimens were obturated with gutta percha and a eugenol-based sealer. Dowel space preparation and dowel cementation were completed 1 week after obturation. Ten-millimeter-deep dowel spaces were prepared using dowel drills with 4 different diameters: size 5 Parapost drill (Group 1; Coltene/Whaledent, Mahwah, NJ); size 5.5 Parapost drill (Group 2; Coltene/Whaledent); size 6 Gates Glidden drill (Group 3; Dentsply/Maillefer); size 6 Parapost drill (Group 4; Coltene/Whaledent). Size 5 Paraposts were then cemented with Panavia 21 OP. After 48 hours of storage, specimens were mounted in polyvinyl chloride (PVC) pipe with acrylic, and the dowels were removed in tensile mode using a universal testing machine at 1 mm/min, with data recorded in kilograms.
RESULTS: (all values in kilograms) Group 1 (Parapost 5) mean = 15.07, 95% confidence interval (CI) = +/-6.11; Group 2 (Parapost 5.5) mean = 25.60, 95% CI = +/-7.39; Group 3 (Gates-Glidden 6) mean = 43.15, 95% CI = +/-7.81; Group 4 (Parapost 6) mean = 37.75, 95% CI = +/-6.35. Analysis of variance and Bonferroni tests revealed that Group 3 had significantly greater mean retention strength values than Group 1 and Group 2 (p <.05), and that Group 4 had significantly greater mean retention strength values than Group 1 (p <.05).
CONCLUSIONS: Paraposts cemented with Panavia 21 OP showed significantly greater retention in oversized dowel spaces compared with dowel spaces prepared with the manufacturers' matched dowel-drill set.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11935506     DOI: 10.1111/j.1532-849x.2002.00019.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  6 in total

1.  Can cement film thickness influence bond strength and fracture resistance of fiber reinforced composite posts?

Authors:  Alice Gonçalves Penelas; Valery Martins Piedade; Ana Carolina Oliveira da Silva Borges; Laiza Tatiana Poskus; Eduardo Moreira da Silva; José Guilherme Antunes Guimarães
Journal:  Clin Oral Investig       Date:  2015-08-29       Impact factor: 3.573

2.  Push-out bond strength of circular and oval-shaped fiber posts.

Authors:  Ivanovic Coniglio; Elisa Magni; Amerigo Cantoro; Cecilia Goracci; Marco Ferrari
Journal:  Clin Oral Investig       Date:  2010-07-27       Impact factor: 3.573

3.  Cement layer thickness and shear stress resistance in cylindrical dowel spaces: pull-out test.

Authors:  M Andreasi Bassi; D Lauritano; M Brizzi; C Andrisani; S Lico; V Candotto
Journal:  Oral Implantol (Rome)       Date:  2017-01-21

4.  Evaluation of the resin cement thicknesses and push-out bond strengths of circular and oval fiber posts in oval-shapes canals.

Authors:  Özgür Er; Kerem Kılıç; Halil İbrahim Kılınç; Tuğrul Aslan; Burak Sağsen
Journal:  J Adv Prosthodont       Date:  2015-02-17       Impact factor: 1.904

5.  Retention of fiber posts to the optimally and over-prepared dowel spaces.

Authors:  Hesham Ibrahim Othman; Mohamed Ibrahim Elshinawy; Khalid Mohamed Abdelaziz
Journal:  J Adv Prosthodont       Date:  2013-02-28       Impact factor: 1.904

6.  Influence of the Cement Film Thickness on the Push-Out Bond Strength of Glass Fiber Posts Cemented in Human Root Canals.

Authors:  Natália Araújo Silva Prado; Reinaldo de Souza Ferreira; Marcos Henrique de Pinho Maurício; Sidnei Paciornik; Mauro Sayão de Miranda
Journal:  Int J Dent       Date:  2016-04-10
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.