Literature DB >> 11933653

Assessment of early chorionic circulation by three-dimensional power Doppler.

Tomislav Hafner1, Asim Kurjak, Biserka Funduk-Kurjak, Ivanka Bekavac.   

Abstract

Three-dimensional power Doppler sonography is a unique instrument that enables assessment of vascular signals within the whole investigated area. Hemodynamical changes included in the process of early placentation are one of the most exciting topics in investigation of early human development. This investigation was designed as an observational cross-sectional study. A group of 25 patients in gestational age five to eleven weeks were recruited for the study. After acquirement of the volume containing three-dimensional power Doppler data of the pregnant uterus, the signals belonging to the chorion were isolated. Vascular 3D measurements were undertaken through 3D color/power histogram and expressed by Vascularization Index (VI) and Vascularization Flow Index (VFI). Volume of the chorion increased exponentially throughout the observation period. The VI and VFI positively correlated with the crown-rump length and chorion volume, and showed gradual increment through the investigation period. This investigation produced results confirming gradual augmentation of the loci and intensity of the intervillous flow in pregnancies between five and eleven gestational weeks.

Entities:  

Mesh:

Year:  2002        PMID: 11933653     DOI: 10.1515/JPM.2002.005

Source DB:  PubMed          Journal:  J Perinat Med        ISSN: 0300-5577            Impact factor:   1.901


  3 in total

1.  Placental volume and vascular flow assessed by 3D power Doppler and adverse pregnancy outcomes.

Authors:  A O Odibo; K R Goetzinger; K M Huster; J K Christiansen; L Odibo; M G Tuuli
Journal:  Placenta       Date:  2011-02-04       Impact factor: 3.481

2.  Use of placental vascularization indices and uterine artery peak systolic velocity in early detection of pregnancies complicated by gestational diabetes, chronic or gestational hypertension, and preeclampsia at risk.

Authors:  Ábel T Altorjay; Andrea Surányi; Tibor Nyári; Gábor Németh
Journal:  Croat Med J       Date:  2017-04-14       Impact factor: 1.351

3.  Assessment of uteroplacental vascularisation in early first-trimester pregnancy with contrast-enhanced ultrasound and 3D power Doppler angiography: protocol for a prospective, cross-sectional, multicentre and non-randomised open study ("HOPE Study").

Authors:  Charline Bertholdt; Marie-Laure Eszto; Mathilde Tournier; Gabriela Hossu; Naoual Mellouki; Aboubaker Cherifi; Olivier Morel
Journal:  BMJ Open       Date:  2019-09-11       Impact factor: 2.692

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.