Literature DB >> 11933031

Capillary isoelectric focusing-mass spectrometry: analysis of protein mixtures from human body fluids.

Nigel J Clarke1, Stephen Naylor.   

Abstract

Isoelectric focusing within a fused silica capillary (cIEF) has proved to be a powerful and practical method for high-resolution separation of analytes from complex biological mixtures. This technique overcomes many of the problems of isoelectric focusing within slab gel media. However current cIEF systems commonly utilize UV detection which limits the detail of analyte structural information that is obtained during analysis. The use of mass spectrometry (MS) as the detection system provides much greater structural information about the detected analytes allowing accurate relative molecular mass (M(r)) determination for proteins and polypeptides. We have constructed a cIEF-MS interface and compared the separation of standard proteins analyzed by cIEF-UV with cIEF-MS. This allowed rapid optimization of the cIEF-MS system performance. Further we have demonstrated the use of MS as a detection system provides accurate M(r) information and can provide analyte modification details. These factors increase the likelihood of absolute identification for physiological proteins within complex in vivo-derived mixtures. To demonstrate the value of cIEF-MS in such analyses we have undertaken an examination of cerebrospinal fluid (CSF), and tentatively identified a number of constituent proteins. We have also analyzed whole blood from control and diabetic patients. We show that glycated alpha- and beta- chains of hemoglobin are found in almost equal abundance in diabetic patient blood. From these results we suggest cIEF-MS is an efficient and useful tool for the separation and examination of in vivo-derived analytes within physiological fluids. Copyright 2002 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11933031     DOI: 10.1002/bmc.159

Source DB:  PubMed          Journal:  Biomed Chromatogr        ISSN: 0269-3879            Impact factor:   1.902


  1 in total

1.  Using size exclusion chromatography-RPLC and RPLC-CIEF as two-dimensional separation strategies for protein profiling.

Authors:  David C Simpson; Seonghee Ahn; Ljiljana Pasa-Tolic; Bogdan Bogdanov; Heather M Mottaz; Andrey N Vilkov; Gordon A Anderson; Mary S Lipton; Richard D Smith
Journal:  Electrophoresis       Date:  2006-07       Impact factor: 3.535

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.