BACKGROUND: The color arrangement test can be applied for early diagnosis of diabetic retinopathy, even small confusion of colors influence clinical diagnosis. It is therefore necessary to be aware of influential factors.
METHODS: Forty-four patients with color-experience (VW-Werk Wolfsburg) were included and devided in two groups: group 1: non-smokers without ophthalmological and systemic diseases (n = 27, 42+/-9 years), group 2: smokers without ophthalmological and systemic diseases (n = 17; 43+/-8 years). The control group 3 (n = 30; 42+/-4 years) included non-smokers and the control group 4 (n = 10; 42+/-8 years) smokers, both groups without color-experience, ophthalmological and systemic diseases. Besides the ophthalmological examinations (visual acuity, refraction, intraocular pressure, slit lamp and fundus examination) the color-vision was tested by the color-arrangement-test Roth 28-hue (E) desaturated monocularly under standard conditions: The background used was black cardboard, illuminated by two Osram fluorescent lamps (L36W/12LDL Daylight) providing 2000 lux at the test table.
RESULTS: Ophthalmological examination in all subjects was without pathological findings. The mean error score in the non-smokers with color-experience (median+/-mean absolute deviation: 48+/-47) was lower than in the non-smokers without color experience (72+/-45; Mann-Withney-U-Test: p = 0.02). The mean error score in the smokers with color-experience (60+/-60) was lower than in the smokers without color-experience (156+/-65; p = 0.0014). No statistically significant difference was found between the measurements of the right and left eye (Wilcoxon-Test: group 1: p = 0.89; group 2: p = 0.9; group 3: p = 0.77; group 4: p = 0.87).
CONCLUSION: Color experience improves the results in color-arrangement-tests like the Roth 28-hue (E) desaturated and should be considered in quantitative evaluation.

Entities:  

Mesh:

Year:  2002        PMID: 11932807     DOI: 10.1055/s-2002-23497

Source DB:  PubMed          Journal:  Klin Monbl Augenheilkd        ISSN: 0023-2165            Impact factor:   0.700


  1 in total

1.  Age-corrected reference values for the Heidelberg multi-color anomaloscope.

Authors:  Florian Rüfer; Benno Sauter; Alexa Klettner; Katja Göbel; Josef Flammer; Carl Erb
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-02-17       Impact factor: 3.117

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.