Literature DB >> 11931302

Single half-wavelength ultrasonic particle filter: predictions of the transfer matrix multilayer resonator model and experimental filtration results.

Jeremy J Hawkes1, W Terence Coakley, Martin Gröschl, Ewald Benes, Sian Armstrong, Paul J Tasker, Helmut Nowotny.   

Abstract

The quantitative performance of a "single half-wavelength" acoustic resonator operated at frequencies around 3 MHz as a continuous flow microparticle filter has been investigated. Standing wave acoustic radiation pressure on suspended particles (5-microm latex) drives them towards the center of the half-wavelength separation channel. Clarified suspending phase from the region closest to the filter wall is drawn away through a downstream outlet. The filtration efficiency of the device was established from continuous turbidity measurements at the filter outlet. The frequency dependence of the acoustic energy density in the aqueous particle suspension layer of the filter system was obtained by application of the transfer matrix model [H. Nowotny and E. Benes, J. Acoust. Soc. Am. 82, 513-521 (1987)]. Both the measured clearances and the calculated energy density distributions showed a maximum at the fundamental of the piezoceramic transducer and a second, significantly larger, maximum at another system's resonance not coinciding with any of the transducer or empty chamber resonances. The calculated frequency of this principal energy density maximum was in excellent agreement with the optimal clearance frequency for the four tested channel widths. The high-resolution measurements of filter performance provide, for the first time, direct verification of the matrix model predictions of the frequency dependence of acoustic energy density in the water layer.

Entities:  

Year:  2002        PMID: 11931302     DOI: 10.1121/1.1448341

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  3 in total

1.  Design, modeling, and experimental validation of an acoustofluidic platform for nanoscale molecular synthesis and detection.

Authors:  M M Binkley; M Cui; W Li; S Tan; M Y Berezin; J M Meacham
Journal:  Phys Fluids (1994)       Date:  2019-08-26       Impact factor: 3.521

Review 2.  Sample preparation: the weak link in microfluidics-based biodetection.

Authors:  Raymond Mariella
Journal:  Biomed Microdevices       Date:  2008-12       Impact factor: 2.838

3.  Numerical and experimental analysis of a hybrid material acoustophoretic device for manipulation of microparticles.

Authors:  Alireza Barani; Peiman Mosaddegh; Shaghayegh Haghjooy Javanmard; Shahrokh Sepehrirahnama; Amir Sanati-Nezhad
Journal:  Sci Rep       Date:  2021-11-11       Impact factor: 4.379

  3 in total