PURPOSE: To evaluate the safety of and time required for a broad range of musculoskeletal interventional procedures performed by using magnetic resonance (MR) imaging guidance with a vertically open 0.5-T unit. MATERIALS AND METHODS: Sixty-three MR imaging-guided procedures were performed. A vertically open MR unit equipped with in-room display monitors allowed interactive freehand MR guidance predominantly with fast spin-echo and gradient-echo sequences. Each procedure was classified in terms of the anatomic location, procedure type, and tissue type involved. The procedures were evaluated for success of needle placement, adequacy of tissue sampling, total procedural time, needle time, number of needle passes, and complications. RESULTS: Procedures consisted of tissue sampling with core-needle (n = 6) or fine-needle aspiration (n = 20) biopsy, corticosteroid or contrast agent injection (n = 19), joint cyst aspiration (n = 7), and drainage (n = 11). Successful needle placement was achieved in all 63 cases. Cytologic and histologic tissue samples were sufficient for pathologic diagnosis in 24 of 26 cases. In two cases, complications occurred: transient local bleeding and a brief vasovagal episode. The mean total procedural time was 64.8 minutes; the mean needle time, 26.2 minutes; and the mean number of needle passes per patient, 1.6. CONCLUSION: With use of a vertically open MR unit, MR-guided interventional procedures involving bone, soft tissue, intervertebral disks, and joints are safe and sufficiently rapid for use in clinical practice.
PURPOSE: To evaluate the safety of and time required for a broad range of musculoskeletal interventional procedures performed by using magnetic resonance (MR) imaging guidance with a vertically open 0.5-T unit. MATERIALS AND METHODS: Sixty-three MR imaging-guided procedures were performed. A vertically open MR unit equipped with in-room display monitors allowed interactive freehand MR guidance predominantly with fast spin-echo and gradient-echo sequences. Each procedure was classified in terms of the anatomic location, procedure type, and tissue type involved. The procedures were evaluated for success of needle placement, adequacy of tissue sampling, total procedural time, needle time, number of needle passes, and complications. RESULTS: Procedures consisted of tissue sampling with core-needle (n = 6) or fine-needle aspiration (n = 20) biopsy, corticosteroid or contrast agent injection (n = 19), joint cyst aspiration (n = 7), and drainage (n = 11). Successful needle placement was achieved in all 63 cases. Cytologic and histologic tissue samples were sufficient for pathologic diagnosis in 24 of 26 cases. In two cases, complications occurred: transient local bleeding and a brief vasovagal episode. The mean total procedural time was 64.8 minutes; the mean needle time, 26.2 minutes; and the mean number of needle passes per patient, 1.6. CONCLUSION: With use of a vertically open MR unit, MR-guided interventional procedures involving bone, soft tissue, intervertebral disks, and joints are safe and sufficiently rapid for use in clinical practice.
Authors: Stephan Zangos; Theodor Vetter; Frank Huebner; Montu Tuwari; Florian Mayer; Katrin Eichler; M-L Hansmann; A Wetter; C Herzog; Thomas J Vogl Journal: Eur Radiol Date: 2005-12-13 Impact factor: 5.315
Authors: Lorenzo Monfardini; Lorenzo Preda; Gaetano Aurilio; Stefania Rizzo; Vincenzo Bagnardi; Giuseppe Renne; Sara Maccagnoni; Paolo Della Vigna; Disalvatore Davide; Massimo Bellomi Journal: Radiol Med Date: 2014-04-04 Impact factor: 3.469
Authors: Risto Ojala; Pekka Kerimaa; Martti Lakovaara; Pekka Hyvönen; Petri Lehenkari; Osmo Tervonen; Roberto Blanco-Sequeiros Journal: Skeletal Radiol Date: 2011-02-15 Impact factor: 2.199
Authors: Iris-Melanie Noebauer-Huhmann; Gabriele Amann; Martin Krssak; Joannis Panotopoulos; Pavol Szomolanyi; Michael Weber; Christian Czerny; Martin Breitenseher; Guenther Grabner; Wolfgang Bogner; Stefan Nemec; Martin Dominkus; Philipp Funovics; Reinhard Windhager; Siegfried Trattnig Journal: Eur Radiol Date: 2015-01-11 Impact factor: 5.315