Literature DB >> 11929169

Comparison of methods for fluorescent detection of viable, dead, and total Escherichia coli O157:H7 cells in suspensions and on apples using confocal scanning laser microscopy following treatment with sanitizers.

Scott L Burnett1, Larry R Beuchat.   

Abstract

The influence of treating Escherichia coli O157:H7 cells labeled with an enhanced green fluorescent protein (EGFP) plasmid with 20 microg/ml active chlorine, 100 mg/ml hydrogen peroxide, and 80 mg/ml acetic acid on fluorescence intensity was determined. In addition, fluorescent staining methods to differentiate viable and dead E. coli O157:H7 cells on the cuticle of Red Delicious cv. apples following treatment with water or 200 microg/ml active chlorine were evaluated. Suspensions of E. coli O157:H7 EGFP+ cells were exposed to chemical treatment solutions for 0, 30, 60, 120, or 300 s before populations (log10 cfu/ml) were determined by surface plating, and fluorescence intensities of suspensions and individual cells were measured using spectrofluorometry and confocal scanning laser microscopy (CSLM), respectively. The relative fluorescence intensity of suspensions and individual cells changed upon exposure to various treatments. Results indicate that the use of EGFP to tag E. coli O157:H7 may not be appropriate for investigations seeking to microscopically differentiate viable and dead cells on produce following surface treatment with sanitizers. SYTOX Orange and SYTOX Green nucleic acid stains fluorescently labeled dead E. coli O157:H7 cells attached to apple cuticles more intensely than did propidium iodide. A cross-signal occurred between CSLM photomultipliers when examining tissues treated with SYTOX Orange to detect dead cells and antibody labeled with Alexa Fluor 488 to detect total (dead and viable) cells. Because of the possibility of cross-signal resulting in an overestimation of the number of dead cells on apples and, perhaps, other produce treated with these stains, SYTOX Green is preferred to detect dead cells and antibody labeled with Alexa Fluor 594 is preferred to detect the total number of cells on apple surfaces following treatment with sanitizers. The performance of SYTOX Green in combination with Alexa Fluor 594 to detect dead and total cells of E. coli O157:H7 on other produce remains to be determined.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11929169     DOI: 10.1016/s0168-1605(01)00714-0

Source DB:  PubMed          Journal:  Int J Food Microbiol        ISSN: 0168-1605            Impact factor:   5.277


  2 in total

1.  Development of an internal control for evaluation and standardization of a quantitative PCR assay for detection of Helicobacter pylori in drinking water.

Authors:  Keya Sen; Nancy A Schable; Dennis J Lye
Journal:  Appl Environ Microbiol       Date:  2007-09-28       Impact factor: 4.792

2.  Comparison of three neutralizing broths for environmental sampling of low levels of Listeria monocytogenes desiccated on stainless steel surfaces and exposed to quaternary ammonium compounds.

Authors:  Fengmin Li; Zhihan Xian; Hee Jin Kwon; Jiyoon Yoo; Laurel Burall; Stuart J Chirtel; Thomas S Hammack; Yi Chen
Journal:  BMC Microbiol       Date:  2020-11-02       Impact factor: 3.605

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.