| Literature DB >> 11927825 |
Hwan T Hee1, Mohammad E Majd, Richard T Holt, David Pienkowski.
Abstract
There is no scientific consensus on the role of posterior instrumentation in vertebral osteomyelitis. No study has examined the use of titanium cages to reconstruct the anterior column of the spine with vertebral osteomyelitis. Here the authors evaluated the efficacy of using titanium mesh cages anteriorly and posterior instrumentation after anterior debridement in the surgical treatment of vertebral osteomyelitis. In one center, 21 consecutive patients had surgery for vertebral osteomyelitis. The mean follow-up time was 67 months (range, 24 to 120 months). Ten patients received supplemental posterior instrumentation. Five patients had reconstruction of the anterior column with titanium cages. Greater improvement in sagittal alignment was noted for patients with cages implanted (p = 0.0009) and for those with posterior instrumentation (p = 0.005). Patients who received cages had greater (p = 0.0006) correction of their coronal alignment than did those patients without cages. A trend toward fewer postoperative complications emerged for patients who had posterior stabilization or titanium cages. These results support the use of posterior stabilization and titanium cages in the surgical treatment of vertebral osteomyelitis.Entities:
Mesh:
Substances:
Year: 2002 PMID: 11927825 DOI: 10.1097/00024720-200204000-00010
Source DB: PubMed Journal: J Spinal Disord Tech ISSN: 1536-0652