Literature DB >> 11927200

Accuracy of blood pressure measurement and anthropometry among volunteer observers in a large community survey.

Claire Adams1, Valerie Burke, Lawrie J Beilin.   

Abstract

The Busselton Survey is a population survey that is held about every three years. In 1994-1995 a re-survey was held of all past participants and 8,502 attended. Financial constraints precluded employing staff for data collection for blood pressure and anthropometry, these therefore were collected by unpaid lay volunteers. Quality control by a health professional was critical to the assessment and maintenance of accuracy in these measurements. For blood pressure three readings were taken simultaneously by a quality control person and the volunteer using a dual stethoscope. Duplicate anthropometric measurements were taken by a criterion anthropometrist and the volunteer. Inter and intra-observer technical errors of measurement (TEM) were calculated. Sixty-two volunteers were trained to take BP measurements; of these, 38 collected data, and 63 were trained in anthropometry; of these, 30 were suitable as measurers. Training was conducted on a group and individual basis by the quality assurance person for the study both in the Perth metropolitan area and rural Busselton. The TEM for SBP was 1.6 mm Hg (SD 1.0 mm Hg) and 1.5 mm Hg (SD 0.8) for DBP. For skin-folds intra-observer TEM ranged from 0.6 mm to 1.0 mm. Between-observer TEM ranged from 2.1 mm to 5.4 mm. For limb and waist circumferences, intra-observer TEM ranged from 0.3 cm to 1.6 cm. Between-observer TEM for circumferences ranged from 0.5 cm to 1.9 cm. Unpaid volunteer measurers can, if carefully trained and supervised, provide acceptable blood pressure data and anthropometry in large population surveys.

Entities:  

Mesh:

Year:  2002        PMID: 11927200     DOI: 10.1016/s0895-4356(01)00492-9

Source DB:  PubMed          Journal:  J Clin Epidemiol        ISSN: 0895-4356            Impact factor:   6.437


  3 in total

1.  Beyond the Evidence of the New Hypertension Guidelines. Blood pressure measurement - is it good enough for accurate diagnosis of hypertension? Time might be in, for a paradigm shift (I).

Authors:  Cornel Pater
Journal:  Curr Control Trials Cardiovasc Med       Date:  2005-04-06

2.  Men's Educational Group Appointments in Rural Nicaragua.

Authors:  Bruce B Campbell; Hugo Gonzalez; McKenzie Campbell; Kent Campbell
Journal:  Am J Mens Health       Date:  2016-11-24

3.  Literacy and motivation for the prevention and control of hypertension among female community health volunteers: a qualitative study from Nepal.

Authors:  Dinesh Neupane; Craig S Mclachlan; Rupesh Gautam; Shiva Raj Mishra; Michael Thorlund; Mette Schlütter; Per Kallestrup
Journal:  Glob Health Action       Date:  2015-12-15       Impact factor: 2.640

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.