Literature DB >> 11924977

Biomolecular recognition on well-characterized beads packed in microfluidic channels.

Tione Buranda1, Jinman Huang, Victor H Perez-Luna, Brett Schreyer, Larry A Sklar, Gabriel P Lopez.   

Abstract

We describe a new approach for the analysis of biomolecular recognition in microfluidic channels. The method involves real-time detection of soluble molecules binding to receptor-bearing microspheres, sequestered in affinity column format inside a microfluidic channel. Identification and quantitation of analytes occurs via direct fluorescence measurements or fluorescence resonance energy transfer (FRET). We establish a model system that detects the FLAG epitope. The assay can potentially detect subfemtomole quantities of antibody with a high signal-to-noise ratio and a large dynamic range spanning nearly 4 orders of magnitude in analyte concentration in microliter-to-submicroliter volumes of analyte fluid. Kinetic and equilibrium constants for the reaction of this receptor-ligand pair are obtained through modeling of kinetic responses of the affinity microcolumn and are consistent with those obtained by flow cytometry. Because of the correlation between kinetic and equilibrium data obtained for the microcolumns, quantitative analysis can be done prior to the steady-state end point of the recognition reaction. This method has the promise of combining the utility of affinity chromatography with the advantage of direct, quantitative, and real-time analysis and the cost-effectiveness of microanalytical devices. The approach has the potential to be generalized to a host of bioaffinity assay methods including analysis of protein complexes and molecular assembly and microsystem-based multianalyte determinations.

Mesh:

Substances:

Year:  2002        PMID: 11924977     DOI: 10.1021/ac0109624

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  6 in total

1.  Efficient manipulation of microparticles in bubble streaming flows.

Authors:  Cheng Wang; Shreyas V Jalikop; Sascha Hilgenfeldt
Journal:  Biomicrofluidics       Date:  2012-03-15       Impact factor: 2.800

2.  Dielectrically Addressable Microspheres Engineered Using Self-Assembled Monolayers.

Authors:  Jody Vykoukal; Daynene Mannering Vykoukal; Susan Sharma; Frederick F Becker; Peter R C Gascoyne
Journal:  Langmuir       Date:  2003-03-18       Impact factor: 3.882

3.  The development of quantum dot calibration beads and quantitative multicolor bioassays in flow cytometry and microscopy.

Authors:  Yang Wu; Samuel K Campos; Gabriel P Lopez; Michelle A Ozbun; Larry A Sklar; Tione Buranda
Journal:  Anal Biochem       Date:  2007-02-13       Impact factor: 3.365

4.  Quantum dots for quantitative flow cytometry.

Authors:  Tione Buranda; Yang Wu; Larry A Sklar
Journal:  Methods Mol Biol       Date:  2011

5.  Microfluidic, bead-based assay: Theory and experiments.

Authors:  Jason A Thompson; Haim H Bau
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2009-09-04       Impact factor: 3.205

Review 6.  Biomimetic silica microspheres in biosensing.

Authors:  Sireesha Chemburu; Kyle Fenton; Gabriel P Lopez; Reema Zeineldin
Journal:  Molecules       Date:  2010-03-17       Impact factor: 4.411

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.