Literature DB >> 11924700

Determination of firing distance using the rhodizonate staining technique.

W Marty1, T Sigrist, D Wyler.   

Abstract

The histological staining technique using rhodizonate is also effective for the determination of the firing distance by examining the distribution and intensity of the staining reaction. The differentiation between absolute close-range shots and long-range shots is generally possible without any doubt. The method is not recommended for routine examinations but it is very useful for cases lacking the possibility to investigate smoke and powder deposits in a criminalistic manner, i.e. surgical skin biopsies of hospitalised victims and skin highly altered by the effects of fire, water or by post-mortem decomposition.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11924700     DOI: 10.1007/s004140100220

Source DB:  PubMed          Journal:  Int J Legal Med        ISSN: 0937-9827            Impact factor:   2.686


  5 in total

1.  Detachment of the periosteum and soot staining of its underside in contact shots to the cerebral cranium.

Authors:  M Faller-Marquardt; M Bohnert; S Pollak
Journal:  Int J Legal Med       Date:  2004-09-29       Impact factor: 2.686

2.  MicroCT detection of gunshot residue in fresh and decomposed firearm wounds.

Authors:  Giovanni Cecchetto; Alessandro Amagliani; Chiara Giraudo; Paolo Fais; Fabiano Cavarzeran; Massimo Montisci; Giampietro Feltrin; Guido Viel; Santo Davide Ferrara
Journal:  Int J Legal Med       Date:  2011-11-16       Impact factor: 2.686

3.  Estimation of the firing distance through micro-CT analysis of gunshot wounds.

Authors:  Giovanni Cecchetto; Chiara Giraudo; Alessandro Amagliani; Guido Viel; Paolo Fais; Fabiano Cavarzeran; Giampietro Feltrin; Santo Davide Ferrara; Massimo Montisci
Journal:  Int J Legal Med       Date:  2010-12-01       Impact factor: 2.686

4.  Assets and pitfalls of chemical and microscopic analyses on gunshot residues in skeletonized bodies: a report of five cases.

Authors:  Alberto Amadasi; Daniele Gibelli; Debora Mazzarelli; Davide Porta; Daniel Gaudio; Dominic Salsarola; Alberto Brandone; Agostino Rizzi; Cristina Cattaneo
Journal:  Int J Legal Med       Date:  2014-11-14       Impact factor: 2.686

5.  The determination of firing distance applying a microscopic quantitative method and confocal laser scanning microscopy for detection of gunshot residue particles.

Authors:  Margherita Neri; Emanuela Turillazzi; Irene Riezzo; Vittorio Fineschi
Journal:  Int J Legal Med       Date:  2006-07-22       Impact factor: 2.791

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.