Literature DB >> 11922216

Progressive bone adaptation of titanium implants during and after orthodontic load in humans.

Paolo Trisi1, Alberto Rebaudi.   

Abstract

The aim of the present work was the evaluation of implant stability and periimplant bone reaction by histologic and clinical evaluation after therapeutic orthodontic loads. Forty-one adult patients received titanium implants as an orthodontic anchorage device; 12 patients received a retromolar or palatal implant to obtain tooth movement. Seven implants were removed at the end of the orthodontic therapy, after 2, 4, 6, and 12 months of orthodontic load, and processed for histologic examination. It was possible to distalize maxillary and mandibular molars and a group of teeth (molars and premolars), and to obtain tipping, uprighting, intrusion, extrusion, and transfer of anchorage in other parts of the mouth. The results showed that orthodontic therapy is facilitated and quickened by the use of implants. All implants remained stable in the bone up to 12 months of loading, and all were osseointegrated. Microfractures, microcracks, and microcalli were observed around implants that had been placed in both low- and high-density bone. The remodeling rate was still elevated after 18 months.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11922216

Source DB:  PubMed          Journal:  Int J Periodontics Restorative Dent        ISSN: 0198-7569            Impact factor:   1.840


  5 in total

1.  Long-term follow-up of dental single implants under immediate orthodontic load.

Authors:  Lisiane Meira Palagi; Carlos Eduardo Sabrosa; Eveline C B Gava; Tiziano Baccetti; Jose Augusto M Miguel
Journal:  Angle Orthod       Date:  2010-09       Impact factor: 2.079

2.  Peri-implant evaluation of osseointegrated implants subjected to orthodontic forces: results after three years of functional loading.

Authors:  Bruna de Rezende Marins; Suy Ellen Pramiu; Mauro Carlos Agner Busato; Luiz Carlos Marchi; Adriane Yaeko Togashi
Journal:  Dental Press J Orthod       Date:  2016 Mar-Apr

3.  Assessing double Acid-etched implants submitted to orthodontic forces and used as prosthetic anchorages in partially edentulous patients.

Authors:  Rugani de Cravero Marta; Ibañez Juan Carlos
Journal:  Open Dent J       Date:  2008-03-08

4.  Effect of PTH and corticotomy on implant movement under mechanical force.

Authors:  Jiyeon Kim; Heon-Young Kim; Won-Ho Kim; Jin-Woo Kim; Min-Ji Kim
Journal:  BMC Oral Health       Date:  2020-11-10       Impact factor: 2.757

5.  Evaluation of the effects of photobiomodulation on orthodontic movement of molar verticalization with mini-implant: A randomized double-blind protocol study.

Authors:  Felipe Murakami-Malaquias-Silva; Ellen Perim Rosa; Paulo André Almeida; Tânia Oppido Schalch; Carlos Alberto Tenis; Renata Matalon Negreiros; Ricardo Fidos Horliana; Aguinaldo Silva Garcez; Marcella Ueda R Fernandes; Andre Tortamano; Lara Jansiski Motta; Sandra Kalil Bussadori; Anna Carolina Ratto Tempestini Horliana
Journal:  Medicine (Baltimore)       Date:  2020-03       Impact factor: 1.817