Literature DB >> 11921240

Different quantitation approaches for xenobiotics in human urine samples by liquid chromatography/electrospray tandem mass spectrometry.

Juan V Sancho1, Oscar J Pozo, Francisco J López, Félix Hernández.   

Abstract

The potential of liquid chromatography combined with tandem mass spectrometry (LC/MS/MS) for the determination of pesticide metabolites in human urine at the sub-ppb level is explored. Metabolites from two organophosphorous pesticides, 4-nitrophenol (from parathion and parathion-methyl) and 3-methyl-4-nitrophenol (from fenitrothion), are taken as model analytes to conduct this study. After direct injection of the urine sample (10 microL), different approaches were evaluated in order to achieve correct quantitation of analytes using an electrospray ionisation (ESI) interface. Thus, the feasibility of using external calibration was checked versus the use of different isotope-labeled internal standards. The advantages of applying coupled-column liquid chromatography (LC/LC) as an efficient clean-up without any type of sample manipulation are also discussed. The combination of LC/LC with ESI-MS/MS allows the direct analysis of free metabolites in urine, as the automated clean-up performed by the coupled-column technique is sufficient for the removal of interferences that suppress the ionisation of analytes in the ESI source. Using this procedure with external calibration, good precision and recoveries, and detection limits below 1 ng/mL are reached with analysis run times of around 8 min. The hyphenated technique LC/LC/ESI-MS/MS is proved to be a powerful analytical tool, allowing the rapid, sensitive and selective determination of 4-nitrophenol and 3-methyl-4-nitrophenol in human urine without any sample treatment. Copyright 2002 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11921240     DOI: 10.1002/rcm.617

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  4 in total

1.  Determination of glyphosate in surface water with high organic matter content.

Authors:  Vahur Toss; Ivo Leito; Sergei Yurchenko; Rene Freiberg; Anneli Kruve
Journal:  Environ Sci Pollut Res Int       Date:  2017-02-13       Impact factor: 4.223

2.  Evaluation of protein quantification using standard peptides containing single conservative amino acid replacements.

Authors:  Elizabeth R Remily-Wood; John M Koomen
Journal:  J Mass Spectrom       Date:  2012-02       Impact factor: 1.982

3.  Quantitative hydrophilic interaction chromatography-mass spectrometry analysis of N-acetylneuraminic acid and N-acetylmannosamine in human plasma.

Authors:  Yifan Shi; Xin Xu; Meng Fang; Michael Zhang; Yinghe Li; Brad Gillespie; Selwyn Yorke; Nora Yang; John C McKew; William A Gahl; Marjan Huizing; Nuria Carrillo-Carrasco; Amy Qiu Wang
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2015-07-17       Impact factor: 3.205

4.  Using ambient mass spectrometry and LC-MS/MS for the rapid detection and identification of multiple illicit street drugs.

Authors:  Chien-Hua Chiang; Hei-Hwa Lee; Bai-Hsiun Chen; Yi-Ching Lin; Yu-Ying Chao; Yeou-Lih Huang
Journal:  J Food Drug Anal       Date:  2018-12-04       Impact factor: 6.157

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.