Literature DB >> 11919477

Sonographic evaluation of breast nodules: comparison of conventional, real-time compound, and pulse-inversion harmonic images.

Bo Kyoung Seo1, Yu Whan Oh, Hyung Rae Kim, Hong Weon Kim, Chang Ho Kang, Nam Joon Lee, Jung Hyuk Kim, Bum Jin Park, Kyu Ran Cho, June Young Lee, Ki Yeoul Lee, Jeoung Won Bae.   

Abstract

OBJECTIVE: To compare the use of conventional, real-time compound, and pulse-inversion harmonic imaging in the evaluation of breast nodules.
MATERIALS AND METHODS: Fifty-two breast nodules were included in this study, conducted between May and December 2000, in which conventional, real-time compound, and pulse-inversion harmonic images were obtained in the same plane. Three radiologists, each blinded to the interpretations of the other two, evaluated the findings, characterizing the lesions and ranking the three techniques from grade 1, the worst, to grade 3, the best. Lesion conspicuity was assessed, and lesions were also characterized in terms of their margin, clarity of internal echotexture, and clarity of posterior echo pattern. The three techniques were compared using Friedman's test, and interobserver agreement in image interpretation was assessed by means of the intraclass correlation coefficient.
RESULTS: With regard to lesion conspicuity, margin, and internal echotexture of the nodules, real-time compound imaging was the best technique (p < 0.05); in terms of posterior echo pattern, the best was pulse-inversion harmonic imaging (p < 0.05). Real-time compound and pulse inversion harmonic imaging were better than conventional sonography in all evaluative aspects. Interobserver agreement was greater than moderate.
CONCLUSION: Real-time compound and pulse-inversion harmonic imaging procedures are superior to conventional sonography in terms of both lesion conspicuity and the further characterization of breast nodules. Real-time compound imaging is the best technique for evaluation of the margin and internal echotexture of nodules, while pulse-inversion harmonic imaging is very effective for the evaluation of the posterior echo patterns.

Entities:  

Mesh:

Year:  2002        PMID: 11919477      PMCID: PMC2713985          DOI: 10.3348/kjr.2002.3.1.38

Source DB:  PubMed          Journal:  Korean J Radiol        ISSN: 1229-6929            Impact factor:   3.500


  25 in total

1.  Comparison of harmonic and conventional power Doppler ultrasonography for assessment of slow flow in hyperechoic tissue: experimental study using a Doppler phantom.

Authors:  A Y Kim; T K Kim; Y H Kim; J K Han; B I Choi
Journal:  Invest Radiol       Date:  2000-02       Impact factor: 6.016

2.  Pulse inversion imaging of liver blood flow: improved method for characterizing focal masses with microbubble contrast.

Authors:  P N Burns; S R Wilson; D H Simpson
Journal:  Invest Radiol       Date:  2000-01       Impact factor: 6.016

3.  Sonographic appearance and ultrasound-guided fine-needle aspiration biopsy of breast carcinomas smaller than 1 cm3.

Authors:  B D Fornage; N Sneige; M J Faroux; E Andry
Journal:  J Ultrasound Med       Date:  1990-10       Impact factor: 2.153

4.  Dynamic tests in real-time breast echography.

Authors:  E Ueno; E Tohno; S Soeda; Y Asaoka; K Itoh; J C Bamber; M Blaszçzyk; J Davey; J A Mckinna
Journal:  Ultrasound Med Biol       Date:  1988       Impact factor: 2.998

5.  Diagnostic value of different interpretative criteria in real-time sonography of the breast.

Authors:  W J Leucht; D R Rabe; K D Humbert
Journal:  Ultrasound Med Biol       Date:  1988       Impact factor: 2.998

6.  Real-time breast sonography: application in 300 consecutive patients.

Authors:  S V Hilton; G R Leopold; L K Olson; S A Willson
Journal:  AJR Am J Roentgenol       Date:  1986-09       Impact factor: 3.959

7.  Solid breast nodules: use of sonography to distinguish between benign and malignant lesions.

Authors:  A T Stavros; D Thickman; C L Rapp; M A Dennis; S H Parker; G A Sisney
Journal:  Radiology       Date:  1995-07       Impact factor: 11.105

8.  Breast imaging and the standard of care for the symptomatic patient.

Authors:  D B Kopans
Journal:  Radiology       Date:  1993-06       Impact factor: 11.105

9.  Fibroadenoma of the breast: sonographic appearance.

Authors:  B D Fornage; J G Lorigan; E Andry
Journal:  Radiology       Date:  1989-09       Impact factor: 11.105

Review 10.  Breast ultrasonography.

Authors:  P M Jokich; D L Monticciolo; Y T Adler
Journal:  Radiol Clin North Am       Date:  1992-09       Impact factor: 2.303

View more
  6 in total

1.  Phase-inversion tissue harmonic imaging compared to fundamental B-mode ultrasound in the evaluation of the pathology of large and small bowel.

Authors:  T Schmidt; C Hohl; P Haage; D Honnef; A H Mahnken; G Krombach; W Piroth; R W Günther
Journal:  Eur Radiol       Date:  2005-04-08       Impact factor: 5.315

2.  Comparison of conventional B-scan, tissue harmonic imaging, compound imaging and tissue harmonic compound imaging in neck lesion characterisation.

Authors:  Alessandro Bozzato; Anne Loika; Joachim Hornung; Michael Koch; Johannes Zenk; Wolfgang Uter; Heinrich Iro
Journal:  Eur Arch Otorhinolaryngol       Date:  2010-04-27       Impact factor: 2.503

3.  Comparison of fundamental sonography, tissue-harmonic sonography, fundamental compound sonography, and tissue-harmonic compound sonography for focal hepatic lesions.

Authors:  Se Hyung Kim; Jeong Min Lee; Kwang Gi Kim; Jong Hyo Kim; Joon Koo Han; Jae Young Lee; Byung Ihn Choi
Journal:  Eur Radiol       Date:  2006-03-29       Impact factor: 7.034

4.  Value of tissue harmonic imaging (THI) and contrast harmonic imaging (CHI) in detection and characterisation of breast tumours.

Authors:  D- A Clevert; E M Jung; K-P Jungius; K Ertan; R Kubale
Journal:  Eur Radiol       Date:  2006-07-06       Impact factor: 5.315

5.  Comparative analysis of logistic regression, support vector machine and artificial neural network for the differential diagnosis of benign and malignant solid breast tumors by the use of three-dimensional power Doppler imaging.

Authors:  Shou-Tung Chen; Yi-Hsuan Hsiao; Yu-Len Huang; Shou-Jen Kuo; Hsin-Shun Tseng; Hwa-Koon Wu; Dar-Ren Chen
Journal:  Korean J Radiol       Date:  2009-08-25       Impact factor: 3.500

6.  A new method for assessing the performance of signal processing filters in suppressing the side lobe level.

Authors:  Mok Kun Jeong; Sung Jae Kwon
Journal:  Ultrasonography       Date:  2020-07-15
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.