Literature DB >> 11918976

Comparison of flat-panel detector and image-intensifier detector for cone-beam CT.

Rika Baba1, Yasutaka Konno, Ken Ueda, Shigeyuki Ikeda.   

Abstract

We evaluated a flat-panel detector (FPD) (scintillator screen and a-Si photo-sensor array) for use in a cone-beam computed tomography (CT) detector and compared it with an image-intensifier detector (IID). The FPD cone-beam CT system has a higher spatial resolution than the IID system. At equal pixel sizes, the standard deviation of noise intensity of the FPD system is equal to that of the IID system. However, the circuit noise of the FPD must be reduced, especially at low doses. Our evaluations show that the FPD system has a strong potential for use as a cone-beam CT detector because of high-spatial resolution.

Entities:  

Mesh:

Year:  2002        PMID: 11918976     DOI: 10.1016/s0895-6111(02)00008-3

Source DB:  PubMed          Journal:  Comput Med Imaging Graph        ISSN: 0895-6111            Impact factor:   4.790


  11 in total

Review 1.  Modern dental imaging: a review of the current technology and clinical applications in dental practice.

Authors:  Bart Vandenberghe; Reinhilde Jacobs; Hilde Bosmans
Journal:  Eur Radiol       Date:  2010-06-11       Impact factor: 5.315

2.  Evaluation of vascular supply with cone-beam computed tomography during intraarterial chemotherapy for a skull base tumor.

Authors:  Reiichi Ishikura; Kumiko Ando; Yuki Nagami; Satoshi Yamamoto; Koui Miura; Ajaya Raj Pande; Tosyiko Yamano; Shozo Hirota; Norio Nakao
Journal:  Radiat Med       Date:  2006-06

Review 3.  State-of-the-art on cone beam CT imaging for preoperative planning of implant placement.

Authors:  Maria Eugenia Guerrero; Reinhilde Jacobs; Miet Loubele; Filip Schutyser; Paul Suetens; Daniel van Steenberghe
Journal:  Clin Oral Investig       Date:  2006-02-16       Impact factor: 3.573

Review 4.  [Basic principles of flat detector computed tomography (FD-CT)].

Authors:  Y Kyriakou; T Struffert; A Dörfler; W A Kalender
Journal:  Radiologe       Date:  2009-09       Impact factor: 0.635

5.  Accuracy assessment of the axial images obtained from cone beam computed tomography.

Authors:  Francine Kühl Panzarella; J L C Junqueira; L B Oliveira; N S de Araújo; C Costa
Journal:  Dentomaxillofac Radiol       Date:  2011-09       Impact factor: 2.419

Review 6.  Advanced imaging in limb salvage.

Authors:  Cassidy Duran; Jean Bismuth
Journal:  Methodist Debakey Cardiovasc J       Date:  2012 Oct-Dec

Review 7.  Technical aspects of dental CBCT: state of the art.

Authors:  R Pauwels; K Araki; J H Siewerdsen; S S Thongvigitmanee
Journal:  Dentomaxillofac Radiol       Date:  2015       Impact factor: 2.419

Review 8.  4D-DSA: Development and Current Neurovascular Applications.

Authors:  K L Ruedinger; S Schafer; M A Speidel; C M Strother
Journal:  AJNR Am J Neuroradiol       Date:  2020-11-26       Impact factor: 3.825

9.  Utility of C-arm CT in overcoming challenges in patients undergoing Transarterial chemoembolization for hepatocellular carcinoma.

Authors:  Chinmay Kulkarni; K P Sreekumar; Nirmal Kumar Prabhu; Rajesh R Kannan; Srikanth Moorthy
Journal:  Indian J Radiol Imaging       Date:  2014-01

Review 10.  Fundamentals of cone beam computed tomography for a prosthodontist.

Authors:  George Puthenpurayil John; Tatu Elenjickal Joy; Justin Mathew; Vinod R B Kumar
Journal:  J Indian Prosthodont Soc       Date:  2015 Jan-Mar
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.