Literature DB >> 11918582

Patch test results in 542 patients with suspected contact dermatitis in Turkey.

Esra Akasya-Hillenbrand1, Esen Ozkaya-Bayazit.   

Abstract

In this retrospective study, patch test results of 542 patients (303 female and 239 male), referred to our clinic between June 1996 and July 1999, were evaluated. All patients were patch tested with 32 allergens of an extended European standard series, 140 patients were tested with supplemental series, and 246 patients with their own substances. 280 (51.7%) patients had 1 or more positive results but allergic contact dermatitis, according to clinical relevance, was diagnosed in only 190 (67.9%) of these. Nickel sulfate was the most frequent sensitizer (19.1%), followed by potassium dichromate (11.8%), palladium chloride (9.4%), cobalt chloride (8.5%), and thiuram mix (7.7%). Frequencies of contact allergy to fragrance mix (5.5%), balsam of Peru (Myroxylon Pereirae resin) (2%), quaternium-15 (0.6%), and Kathon CG (methylchloroisothiazolinone+methylisothiazolinone) (0.2%) were relatively low, while no positive reactions were obtained to paraben mix in any case. Current clinical relevance to the present dermatitis was most frequently seen with carba mix (96.2%), thiuram mix (95.2%) and potassium dichromate (78.1%), whereas this rate was low for nickel (37.5%). In 85.8% of patients with allergic contact dermatitis, the responsible allergen was detected by testing with the extended standard series alone (18.4% identified by testing with the additional 10 allergens), in 11.6% by testing with the patients' own substances, and in 2.6% by testing with the supplemental series. Occupational contact dermatitis was diagnosed in 77 of the patients with positive reactions (27.5%), most of these being construction workers and house painters who showed relevant sensitizations to potassium dichromate, cobalt chloride, thiuram mix and carba mix. There was no statistically significant difference in the total contact sensitization rate between atopics and non-atopics, but contact sensitivity to nickel sulfate and palladium chloride was significantly higher among atopics. MOAHL index in % was: 44.1/14.2/24.9/ 54.4/2.4. In conclusion, we believe that similar large series of patients would be helpful to delineate the exact profile of contact dermatitis in Turkey.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11918582     DOI: 10.1034/j.1600-0536.2002.460104.x

Source DB:  PubMed          Journal:  Contact Dermatitis        ISSN: 0105-1873            Impact factor:   6.600


  5 in total

1.  An ICP-MS Study for Quantitation of Nickel and Other Inorganic Elements in Urine Samples: Correlation of Patch Test Results with Lifestyle Habits.

Authors:  Selda Mercan; Hayriye Vehid; Sevcan Semen; Ugur Celik; Murat Yayla; Burhan Engin
Journal:  Biol Trace Elem Res       Date:  2021-02-20       Impact factor: 3.738

2.  Comparison of European Standard Patch Test Results of 330 Patients from an Occupational Diseases Hospital.

Authors:  Özge Gündüz; Aslı Aytekin; Engin Tutkun; Hınç Yılmaz
Journal:  Dermatol Res Pract       Date:  2016-10-11

3.  European Standard Series Patch Test Results in Contact Dermatitis Patients in a Tertiary Care Hospital.

Authors:  Ersoy Acer; Hilal Kaya Erdogan; Tayfun Batan; Zeynep Nurhan Saracoglu
Journal:  Sisli Etfal Hastan Tip Bul       Date:  2020-02-25

4.  Incidence of allergic contact sensitization in central Chinese subjects with chronic urticaria.

Authors:  Hao Chen; Guanghui Liu; Nan Huang; Wenjing Li; Xiang Dong; Rongfei Zhu
Journal:  An Bras Dermatol       Date:  2016-04       Impact factor: 1.896

5.  Allergic contact dermatitis pattern in Kuwait: nickel leads the pack. In-depth analysis of nickel allergy based on the results from a large prospective patch test series report.

Authors:  Nawaf Almutairi; Fahad Almutawa
Journal:  Postepy Dermatol Alergol       Date:  2017-05-29       Impact factor: 1.837

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.