Literature DB >> 11918359

Gadolinium-enhanced 3D MR angiography of renal artery stenosis: a pilot comparison of maximum intensity projection, multiplanar reformatting, and 3D volume-rendering postprocessing algorithms.

Visveshwar Baskaran1, F Scott Pereles, Albert A Nemcek, James C Carr, Frank H Miller, John Ly, Elizabeth Krupinski, J Paul Finn.   

Abstract

RATIONALE AND
OBJECTIVES: The authors compared diagnostic accuracy of maximum intensity projection (MIP), multiplanar reformatting (MPR), and three-dimensional (3D) volume rendering (VR) in the evaluation of gadolinium-enhanced 3D magnetic resonance (MR) angiography of the renal arteries. They hypothesized that VR is as accurate as or more accurate than MIP and MPR at depicting renal artery stenosis.
MATERIALS AND METHODS: The study group comprised 28 consecutive patients who underwent gadolinium-enhanced 3D MR angiography of the renal arteries. Studies were postprocessed to display images in MIP, MPR, and VR formats. Digital subtraction angiography (DSA), when performed (nine of 28 patients), was the standard for comparison. For each main renal artery, an estimate of percentage stenosis was made for any stenoses detected by three independent radiologists. For calculation of sensitivity, specificity, and accuracy, MR angiographic stenosis estimates were categorized as mild (0%-39%), moderate (40%-69%), or severe (> or = 70%). DSA stenosis estimates of 70% or greater were considered hemodynamically significant.
RESULTS: Analysis of variance demonstrated MIP estimates of stenosis were statistically greater than VR estimates in two readers and greater than MPR estimates in all readers for all patients. MIP images also showed the largest mean difference from DSA stenosis estimates for all three readers. For both VR and MPR, mean differences between MR angiographic stenoses estimates and DSA estimates reached significance for only one reader, whereas, for MIP versus DSA, mean differences reached significance for all three readers. Although not statistically significant compared with DSA, accuracies of VR (87%) and MPR (89%) were greater than that of MIP (81%).
CONCLUSION: In this pilot study, MIP was the least accurate of the three image display algorithms tested. VR and MPR yielded similar values for each method of comparison.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11918359     DOI: 10.1016/s1076-6332(03)80296-9

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  7 in total

Review 1.  MRA of abdominal vessels: technical advances.

Authors:  Henrik J Michaely; Olaf Dietrich; Kambiz Nael; Sabine Weckbach; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Eur Radiol       Date:  2006-05-24       Impact factor: 5.315

2.  Improved visualization of collateral ligaments of the ankle: multiplanar reconstructions based on standard 2D turbo spin-echo MR images.

Authors:  Sylvain R Duc; Bernard Mengiardi; Christian W A Pfirrmann; Juerg Hodler; Marco Zanetti
Journal:  Eur Radiol       Date:  2006-10-17       Impact factor: 5.315

3.  Contrast-bolus MR angiography of the transplanted kidney with a low-field (0.5-T) scanner: diagnostic accuracy, sensitivity and specificity of images and reconstructions in the evaluation of vascular complications.

Authors:  A Stecco; P Oronzo; F Armienti; C Borraccino; R Fossaceca; L Canalis; A Carriero
Journal:  Radiol Med       Date:  2007-10-21       Impact factor: 3.469

4.  Imaging of temporomandibular joint: approach by direct volume rendering.

Authors:  Antonino Marco Cuccia; Carola Caradonna; Daniele Bruschetta; Gianluigi Vaccarino; Demetrio Milardi
Journal:  J Clin Diagn Res       Date:  2014-11-20

5.  A comparison of 4D time-resolved MRA with keyhole and 3D time-of-flight MRA at 3.0 T for the evaluation of cerebral aneurysms.

Authors:  Qian Wu; Ming-Hua Li
Journal:  BMC Neurol       Date:  2012-07-06       Impact factor: 2.474

6.  In Vivo CT Direct Volume Rendering: A Three-Dimensional Anatomical Description of the Heart.

Authors:  Giuseppina Cutroneo; Daniele Bruschetta; Fabio Trimarchi; Alberto Cacciola; Maria Cinquegrani; Antonio Duca; Giuseppina Rizzo; Emanuela Alati; Michele Gaeta; Demetrio Milardi
Journal:  Pol J Radiol       Date:  2016-01-21

7.  Non-contrast enhanced 3D SSFP MRA of the renal allograft vasculature: a comparison between radial linear combination and Cartesian inflow-weighted acquisitions.

Authors:  Eric M Bultman; Jessica Klaers; Kevin M Johnson; Christopher J François; Mark L Schiebler; Scott B Reeder; Walter F Block
Journal:  Magn Reson Imaging       Date:  2013-10-15       Impact factor: 3.130

  7 in total