Literature DB >> 11918120

The use of heteroduplex analysis of polymerase chain reaction products to support the possible transmission of Legionella pneumophila from a malfunctioning automobile air conditioner.

Ahmet Pinar1, Julio A Ramirez, Laura L Schindler, Richard D Miller, James T Summersgill.   

Abstract

Air conditioner condensates have not been previously associated with cases of Legionnaires' disease. We report the possible transmission of Legionella pneumophila serogroup 1 from a malfunctioning automobile air conditioning system's leaking water onto the floorboard of a car driven for a long distance by the patient. Heteroduplex analysis of polymerase chain reaction products was used to help establish an epidemiologic link between the water specimen and the patient.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11918120     DOI: 10.1086/502025

Source DB:  PubMed          Journal:  Infect Control Hosp Epidemiol        ISSN: 0899-823X            Impact factor:   3.254


  2 in total

1.  Windscreen wiper fluid without added screenwash in motor vehicles: a newly identified risk factor for Legionnaires' disease.

Authors:  Anders Wallensten; Isabel Oliver; Katherine Ricketts; George Kafatos; James M Stuart; Carol Joseph
Journal:  Eur J Epidemiol       Date:  2010-06-08       Impact factor: 8.082

Review 2.  Airborne Infectious Agents and Other Pollutants in Automobiles for Domestic Use: Potential Health Impacts and Approaches to Risk Mitigation.

Authors:  Syed A Sattar; Kathryn E Wright; Bahram Zargar; Joseph R Rubino; M Khalid Ijaz
Journal:  J Environ Public Health       Date:  2016-11-30
  2 in total