Literature DB >> 11917258

Long-term effects of treatment with nasal continuous positive airway pressure on lung function in patients with overlap syndrome.

Javier de Miguel1, Jorge Cabello, José M F Sánchez-Alarcos, Rudolfo Alvarez-Sala, Domingo Espinós, José L Alvarez-Sala.   

Abstract

We assessed the effects of chronic nasal continuous positive airway pressure (CPAP) therapy on lung function in a series of unselected patients with overlap syndrome, and we determined whether there were differences in the response induced by CPAP between hypercapnic (PaCO2 > or =45 mm Hg) and eucapnic patients with overlap syndrome. The study population included 55 unselected patients (48 men, mean age of 58.5 +/- 10.5 years) with a concurrent diagnosis of chronic obstructive pulmonary disease (COPD) and obstructive sleep apnea-hypopnea syndrome (OSAHS) who had been referred to the Department of Pulmonology of our hospital over 2 consecutive years and in whom work-up studies resulted in the prescription of nasal CPAP therapy. An apnea-hypopnea index (AHI) greater than or equal to 10 in the cardiorespiratory polygraphy was required for the diagnosis of OSAHS. A forced expiratory volume in one second (FEV1) less than 80% and FEV1-forced vital capacity (FVC) ratio less than 70% of the reference values were required for the diagnosis of COPD. Control lung function studies and arterial blood gas measurements were performed at 6 and 18 months of CPAP therapy. These patients with overlap syndrome accounted for 28.5% of all patients with OSAHS treated with CPAP during the study period. The mean AHI was 37.3 +/- 26.1 and the mean CPAP level 7.3 +/- 1.3 cm H2O. Thirty-three patients were hypercapnic (PaCO2 > or = 45 mm Hg) and 22 eucapnic. The hypercapnic group had higher AHI value (44.3 +/- 26.9) than the eucapnic group (28.6 +/- 21.9) (P < 0.05). After 6 months of CPAP therapy, there were statistically significant increases in PaO2, FEV1, and FVC, accompanied by significant decreases in PaCO2, serum bicarbonate levels, and alveolar-arterial oxygen difference. Response of overlap syndrome patients to CPAP therapy was superior in the hypercapnic group, particularly in relation to improvement of arterial blood gases. However, statistically significant differences in all parameters for the comparison between 6 and 18 months were not recorded.

Entities:  

Mesh:

Year:  2002        PMID: 11917258     DOI: 10.1007/s11325-002-0003-6

Source DB:  PubMed          Journal:  Sleep Breath        ISSN: 1520-9512            Impact factor:   2.816


  25 in total

1.  Reflex effects of upper airway irritation on total lung resistance and blood pressure.

Authors:  J A NADEL; J G WIDDICOMBE
Journal:  J Appl Physiol       Date:  1962-11       Impact factor: 3.531

2.  Effects of noninvasive positive pressure ventilation on gas exchange and sleep in COPD patients.

Authors:  S L Krachman; A J Quaranta; T J Berger; G J Criner
Journal:  Chest       Date:  1997-09       Impact factor: 9.410

3.  [A comparative study of patients with chronic obstructive pulmonary disease with and without obstructive sleep apnea syndrome].

Authors:  E Calderón-Osuna; C Carmona Bernal; M Arenas Gordillo; M A Fuentes Pradera; A Sánchez Armengol; F Capote Gil
Journal:  Arch Bronconeumol       Date:  1999-12       Impact factor: 4.872

4.  Continuous positive airway pressure reduces work of breathing and dyspnea during weaning from mechanical ventilation in severe chronic obstructive pulmonary disease.

Authors:  B J Petrof; M Legaré; P Goldberg; J Milic-Emili; S B Gottfried
Journal:  Am Rev Respir Dis       Date:  1990-02

5.  Do sleep studies contribute to the management of patients with severe chronic obstructive pulmonary disease?

Authors:  J J Connaughton; J R Catterall; R A Elton; J R Stradling; N J Douglas
Journal:  Am Rev Respir Dis       Date:  1988-08

6.  Treatment effects on carbon dioxide retention in patients with obstructive sleep apnea-hypopnea syndrome.

Authors:  F Han; E Chen; H Wei; Q He; D Ding; K P Strohl
Journal:  Chest       Date:  2001-06       Impact factor: 9.410

7.  Magnetic resonance imaging of the upper airway in obstructive sleep apnea before and after chronic nasal continuous positive airway pressure therapy.

Authors:  C F Ryan; A A Lowe; D Li; J A Fleetham
Journal:  Am Rev Respir Dis       Date:  1991-10

8.  Effects of PEEP on VA/Q mismatching in ventilated patients with chronic airflow obstruction.

Authors:  A Rossi; C Santos; J Roca; A Torres; M A Félez; R Rodriguez-Roisin
Journal:  Am J Respir Crit Care Med       Date:  1994-05       Impact factor: 21.405

9.  Nocturnal nasal continuous positive airway pressure in patients with chronic obstructive pulmonary disease. Influence on waking respiratory muscle function.

Authors:  W S Mezzanotte; D J Tangel; A M Fox; R D Ballard; D P White
Journal:  Chest       Date:  1994-10       Impact factor: 9.410

10.  Severe obstructive sleep apnoea treated with long term nasal continuous positive airway pressure.

Authors:  R W Frith; B R Cant
Journal:  Thorax       Date:  1985-01       Impact factor: 9.139

View more
  18 in total

Review 1.  Sleep-disordered breathing and COPD: the overlap syndrome.

Authors:  Robert L Owens; Atul Malhotra
Journal:  Respir Care       Date:  2010-10       Impact factor: 2.258

2.  Lack of benefit of continuous positive airway pressure on lung function in patients with overlap syndrome.

Authors:  Aidan O'Brien; Kristy Whitman
Journal:  Lung       Date:  2005 Nov-Dec       Impact factor: 2.584

3.  Survival benefit of CPAP favors hypercapnic patients with the overlap syndrome.

Authors:  Philippe Jaoude; Thomas Kufel; Ali A El-Solh
Journal:  Lung       Date:  2014-01-23       Impact factor: 2.584

4.  Survival benefit of CPAP favors hypercapnic patients with the overlap syndrome.

Authors:  Philippe Jaoude; Ali A El-Solh
Journal:  Lung       Date:  2014-06-27       Impact factor: 2.584

Review 5.  Positive airway pressure therapy for heart failure.

Authors:  Takao Kato; Shoko Suda; Takatoshi Kasai
Journal:  World J Cardiol       Date:  2014-11-26

Review 6.  Sleep disorders in chronic obstructive pulmonary disease: etiology, impact, and management.

Authors:  Rohit Budhiraja; Tauseef A Siddiqi; Stuart F Quan
Journal:  J Clin Sleep Med       Date:  2015-03-15       Impact factor: 4.062

7.  Sleep complaints and sleep breathing disorders in upper and lower obstructive lung diseases.

Authors:  Matteo Ferrando; Diego Bagnasco; Valeria Roustan; Giorgio Walter Canonica; Fulvio Braido; Ilaria Baiardini
Journal:  J Thorac Dis       Date:  2016-08       Impact factor: 2.895

8.  Fixed-pressure nCPAP in patients with obstructive sleep apnea (OSA) syndrome and chronic obstructive pulmonary disease (COPD): a 24-month follow-up study.

Authors:  Domenico Maurizio Toraldo; Francesco De Nuccio; Giuseppe Nicolardi
Journal:  Sleep Breath       Date:  2009-09-13       Impact factor: 2.816

9.  Pulmonary function and sleep apnea.

Authors:  Victor Hoffstein; Zoe Oliver
Journal:  Sleep Breath       Date:  2003-12       Impact factor: 2.816

Review 10.  Association of chronic obstructive pulmonary disease and obstructive sleep apnea consequences.

Authors:  Carlos Zamarrón; Vanesa García Paz; Emilio Morete; Felix del Campo Matías
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2008
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.