A comparative multi-laboratory assessment of three factor VIII/von Willebrand factor concentrates.

Emmanuel J Favaloro1, Melinda Bukuya, Teresa Martinelli, Joanne Tzouroutis, Elizabeth Duncan, Katie Welldon, Margaret Collecutt, Heather Aumann, Jim Thom, Grace Gilmore.   

Abstract

Five expert laboratories have participated in a cross-laboratory study to co-evaluate and compare three commercial Factor VIII/von Willebrand factor (VWF) concentrates. A total of nine factor concentrate lots were evaluated, comprising AHF (High Purity) (AHF HP; x3), Biostate (x3) and Humate/Haemate (x3). All laboratories blind tested for FVIII: C, VWF: Ag and VWF: CB, four tested for VWF: RCo, and one performed VWF: Multimers. The study yielded inter-laboratory CVs for VWF: Ag and FVIII:C around 10-15%, and for VWF:CB and VWF:RCo around 20%, significantly lower than those of previous multi-laboratory surveys. All three lots of AHF HP contained in the vicinity of 25 U/ml FVIII:C, around 60-75 U/ml of VWF:Ag, but only 30-45 U/ml of VWF:CB and 40-50 U/ml of VWF:RCo (thus, CB/Ag ratio around 0.5-0.6 and RCo/Ag ratio around 0.6-0.7). Study determined that FVIII: C and VWF: RCo levels were similar to manufacturer assigned levels. Some loss of the high molecular weight (HMW) multimers was observed, together with an intense low molecular weight (LMW) VWF band consistent with some reduction or proteolysis of HMW VWF. All three lots of Humate/Haemate contained in the vicinity of 23-32 U/ml of FVIII:C, 70-105 U/ml of VWF: Ag, 50-90 U/ml of VWF: CB and VWF: RCo (i.e. CB/Ag ratio around 0.6-0.9 and RCo/Ag ratio around 0.6-1.1). Study-determined FVIII: C and VWF: RCo levels were similar to manufacturer-assigned levels. The LMW multimer band seen with AHF HP was also observed with Humate/Haemate. All three lots of Biostate contained in the vicinity of 40-55 U/ml of FVIII:C, 105-170 U/ml of VWF:Ag, 90-150 U/ml of VWF:CB, and 90-135 U/ml of VWF:RCo (i.e. CB/Ag and RCo/Ag ratios around 0.7-1.0). Study-determined FVIII:C levels were similar to manufacturer-assigned levels. The LMW multimer band seen with AHF HP was not observed with Biostate. The defined pattern of increasing CB/ Ag from AHF HP to Humate/Haemate and Biostate was consistently observed in study data from each of the five laboratories. In conclusion, study findings indicate some differences in the retention of functional/ HMW VWF between factor concentrates, and this is expected to have significant implications in terms of clinical efficacy for therapy in VWD.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11916080

Source DB:  PubMed          Journal:  Thromb Haemost        ISSN: 0340-6245            Impact factor:   5.249


  4 in total

Review 1.  Towards personalised therapy for von Willebrand disease: a future role for recombinant products.

Authors:  Emmanuel J Favaloro
Journal:  Blood Transfus       Date:  2016-03-22       Impact factor: 3.443

Review 2.  Human plasma von Willebrand factor/factor VIII complex (Haemate P/Humate-P): in von Willebrand disease and haemophilia A.

Authors:  Natalie J Carter; Lesley J Scott
Journal:  Drugs       Date:  2007       Impact factor: 9.546

3.  Evaluation of von Willebrand factor concentrates by platelet adhesion to collagen using an in vitro flow assay.

Authors:  Anne Riddell; Saravanan Vinayagam; Keith Gomez; Mike Laffan; Tom McKinnon
Journal:  Res Pract Thromb Haemost       Date:  2018-12-07

Review 4.  Human plasma-derived FVIII/VWD concentrate (Biostate): a review of experimental and clinical pharmacokinetic, efficacy and safety data.

Authors:  Paul Harper; Emmanuel J Favaloro; Julie Curtin; Chris Barnes; Scott Dunkley
Journal:  Drugs Context       Date:  2016-04-08
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.