Literature DB >> 11915978

Conduction properties of the crista terminalis and its influence on the right atrial activation sequence in patients with typical atrial flutter.

Hiroshige Yamabe1, Ikuo Misumi, Hironobu Fukushima, Kazuhiro Ueno, Yoshihiro Kimura, Youichi Hokamura.   

Abstract

The conduction properties of the crista terminalis (CT) and its influence on the right atrial activation sequence were analyzed in 14 patients with typical atrial flutter (AF). Atrial mapping was performed with 35 points of the right atrium during typical AF and during atrial pacing performed after linear ablation of inferior vena cava-tricuspid annulus (IVC-TA) isthmus. Atrial pacing was delivered from the septal isthmus at cycle lengths of 600 ms and the tachycardia cycle length (TCL). The right atrial activation sequence and the conduction interval (CI) from the septal to lateral portion of the IVC-TA isthmus were analyzed. During AF, the conduction block line (CBL) (detected by the appearance of double potentials along the CT and craniocaudal activation on the side anterior to CT) was observed along the CT in all patients. The TCL and CI during AF were 254 +/- 19 and 207 +/- 14 ms, respectively. During pacing at a cycle length of 600 ms, the CBL was observed along the CT in four patients, however, a short-circuiting activation across the CT was observed in the remaining ten patients. The CI during pacing at 600 ms was 134 +/- 38 ms, shorter than that during AF (P < .0001). During pacing at the TCL, the CBL was observed along the CT in all patients. The presence of the CBL along the CT prevented a short-circuiting activation across the CT and resulted in the same right atrial activation as observed during AF. With the formation of the CBL, the CI significantly increased to 206 +/- 17 ms and was not different from that during AF. These data suggest that the conduction block along the CT is functional. It was presumed that presence of conduction block at the CT has some relevance to the initiation of typical AF though it was not confirmed.

Entities:  

Mesh:

Year:  2002        PMID: 11915978     DOI: 10.1046/j.1460-9592.2002.00132.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  5 in total

1.  Modelling and imaging cardiac repolarization abnormalities.

Authors:  Y Rudy
Journal:  J Intern Med       Date:  2006-01       Impact factor: 8.989

2.  Mechanisms of transition from normal to reentrant electrical activity in a model of rabbit atrial tissue: interaction of tissue heterogeneity and anisotropy.

Authors:  Oleg V Aslanidi; Mark R Boyett; Halina Dobrzynski; Jue Li; Henggui Zhang
Journal:  Biophys J       Date:  2009-02       Impact factor: 4.033

3.  Upper turnaround point of the reentry circuit of common atrial flutter--three-dimensional mapping and entrainment study.

Authors:  Yasuo Okumura; Ichiro Watanabe; Toshiko Nakai; Kimie Ohkubo; Tatsuya Kofune; Sonoko Ashino; Masayoshi Kofune; Koichi Nagashima; Atsushi Hirayama; Fumio Suzuki
Journal:  J Interv Card Electrophysiol       Date:  2010-11-25       Impact factor: 1.900

4.  Noninvasive electrocardiographic imaging for cardiac electrophysiology and arrhythmia.

Authors:  Charulatha Ramanathan; Raja N Ghanem; Ping Jia; Kyungmoo Ryu; Yoram Rudy
Journal:  Nat Med       Date:  2004-03-14       Impact factor: 53.440

Review 5.  Revisiting an Underrecognized Strategy for Rhythm Management: Hybrid Therapy for Patients who Convert from Atrial Fibrillation to Flutter on Antiarrhythmic Drugs.

Authors:  Fady S Riad; Albert L Waldo
Journal:  J Innov Card Rhythm Manag       Date:  2019-10-15
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.