Literature DB >> 11915452

Current state of cement fixation in THR.

E W Morscher1, D Wirz.   

Abstract

The author surveys important landmarks in the development of total hip arthroplasty, with an accent on implant fixation using acrylic cement. He explains why he personally opted for hybrid prostheses, combining a cemented stem and a cementless socket, in patients over sixty years. Excellent cementless, sockets have been available for a long time; on the femoral side, the first steps were difficult, but several cementless, stems were subsequently developed, which provided excellent long term results. This historical evolution resulted in a very uneven use of cemented versus cementless stems from one country to another in Europe. Cemented implants have enjoyed a renewed popularity over the past few years as a result of several factors, including economical factors. The author discusses the conditions for optimal fixation of a cemented stem; these conditions are not always met satisfactorily, as a number of surgeons obviously stick to a crude cementing technique. The author describes the role of the stem geometry and surface finish, as well as the possible influence of a centralizer; he explains why, based on a correct analysis of the available data, discredit has been unduly cast on cemented stems made of titanium alloy. He insists on one important although often disregarded factor: the specific type of cement used, as better results have clearly been achieved with certain cements than with others. He insists on the necessity to take into account all the elements involved, in order to avoid making erroneous conclusions. He also insists on one very important variable, the quality of the surgical technique. Total hip arthroplasty is likely to make further progress in the future, although we are likely now in the asymptotic portion of an ascending curve. Further improvement in clinical results will result from improvement of currently existing systems and optimization of surgical technique, rather than from the continuous designing of new implants.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11915452

Source DB:  PubMed          Journal:  Acta Orthop Belg        ISSN: 0001-6462            Impact factor:   0.500


  4 in total

1.  [The cemented MS-30 stem. A multi-surgeon series of 333 consecutive cases].

Authors:  M Clauss; T Reitzel; M Pritsch; U J Schlegel; R G Bitsch; V Ewerbeck; H Mau; S J Breusch
Journal:  Orthopade       Date:  2006-07       Impact factor: 1.087

2.  Effect of microencapsulated phase change materials on the thermo-mechanical properties of poly(methyl-methacrylate) based biomaterials.

Authors:  Roberto De Santis; Veronica Ambrogi; Cosimo Carfagna; Luigi Ambrosio; Luigi Nicolais
Journal:  J Mater Sci Mater Med       Date:  2006-12       Impact factor: 3.896

3.  Influence of multiwall carbon nanotube functionality and loading on mechanical properties of PMMA/MWCNT bone cements.

Authors:  Ross Ormsby; Tony McNally; Christina Mitchell; Nicholas Dunne
Journal:  J Mater Sci Mater Med       Date:  2009-12-20       Impact factor: 3.896

4.  Dynamic mechanical behavior of PMMA based bone cements in wet environment.

Authors:  R De Santis; F Mollica; L Ambrosio; L Nicolais; D Ronca
Journal:  J Mater Sci Mater Med       Date:  2003-07       Impact factor: 3.896

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.