Literature DB >> 1191117

[Contribution to the technique of acetabular implantation in total hip arthroplasty (author's transl)].

W Dick, E Morscher.   

Abstract

An operative technique for total hip arthroplasty is described which does not require a guiding instrument to obtain the necessary angles for the acetabular part. Instead, the acetabular rim serves as a guide. The result was examined in 159 cases on the basis of a standard X-ray of the entire pelvis from which the angular relations of the acetabulum could be read or calculated. The values found corresponded to the normal anatomical distribution. The technique is simple and safe. The influence of the angular relationships on the danger of a prosthetic luxation on the one hand and on mobility on the other hand is discussed.

Entities:  

Mesh:

Year:  1975        PMID: 1191117     DOI: 10.1007/bf00416070

Source DB:  PubMed          Journal:  Arch Orthop Unfallchir        ISSN: 0003-9330


  9 in total

1.  Trapezoidal-28 total hip replacement.

Authors:  H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1973-09       Impact factor: 4.176

2.  [X-ray study of total hip prostheses].

Authors:  J P Beauvallet; G Lord; J H Marotte; L E Goutard; J F Elberg
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  1974 Jan-Feb

Review 3.  Total prosthetic replacement of the hip.

Authors:  J Charnley
Journal:  Reconstr Surg Traumatol       Date:  1969

4.  Total hip replacement. An evaluation of the results and technics, 1967-1972.

Authors:  O R Nicholson
Journal:  Clin Orthop Relat Res       Date:  1973-09       Impact factor: 4.176

5.  Total hip prostheses.

Authors:  M E Müller
Journal:  Clin Orthop Relat Res       Date:  1970 Sep-Oct       Impact factor: 4.176

6.  Development of total prosthetic replacement of the hip.

Authors:  G K McKee
Journal:  Clin Orthop Relat Res       Date:  1970 Sep-Oct       Impact factor: 4.176

7.  Urist hip socket and Moore prosthesis without cement for hip replacement.

Authors:  J Debeyre; D Goutallier
Journal:  Clin Orthop Relat Res       Date:  1970 Sep-Oct       Impact factor: 4.176

8.  Low-friction arthroplasty of the hip in rheumatoid arthritis and ankylosing spondylitis.

Authors:  R B Welch; J Charnley
Journal:  Clin Orthop Relat Res       Date:  1970 Sep-Oct       Impact factor: 4.176

9.  Roentgenographic evaluation in total hip replacement. A study of 100 McKee-Farrar prosthetic replacements.

Authors:  D G Mendes
Journal:  Clin Orthop Relat Res       Date:  1973-09       Impact factor: 4.176

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.