Literature DB >> 11905502

Validation of conductance catheter system for quantification of murine pressure-volume loops.

B Yang1, D F Larson, J Beischel, R Kelly, J Shi, R R Watson.   

Abstract

The purpose of this study was to define the validation methods and outcomes of a conductance catheter system specifically for in vivo murine cardiac hemodynamic analysis. To express the relationship between conductance and blood volumes, we used an in vitro model to derive a volume-conductance line. The volume-conductance line was used to compute raw volume from the modified conductance signals. The parallel volume was calibrated with hypertonic (15%) saline injected from extrajugular vein. The ventricular volume was computed by raw volume minus parallel volume. The accuracy of conductance volumetric measurements was validated with a static in situ infusion of calibrated volumes of whole blood injected into arrested left ventricles. In vivo dynamic measurements were performed with 24 C57B1/6 mice, 6 months old; for comparison of established values. The in situ model showed that after calibration, the experimental coefficient, alpha, was equal to 1 and the measured volume by conductance catheter was equal to the true volume of the left ventricle (y = 0.982x + 0.513, p < .0001). For the in vivo models, the end-diastolic volumes and the stroke volumes and cardiac output determined with the conductance catheter system were 17.3 +/- 1.0 microL, 10.6 +/- 0.9 microL, and 6.0 +/- 0.5 mL/min, respectively. We validated the relationship between measured volume by conductance catheter and the true volume and demonstrated the accuracy of the volume-conductance line for conversion of conductance to volume.

Entities:  

Mesh:

Year:  2001        PMID: 11905502     DOI: 10.1080/089419301753435710

Source DB:  PubMed          Journal:  J Invest Surg        ISSN: 0894-1939            Impact factor:   2.533


  9 in total

1.  Diastolic dysfunction is associated with cardiac fibrosis in the senescence-accelerated mouse.

Authors:  Alana L Reed; Atsuko Tanaka; Dan Sorescu; Hong Liu; Euy-Myoung Jeong; Megan Sturdy; Erik R Walp; Samuel C Dudley; Roy L Sutliff
Journal:  Am J Physiol Heart Circ Physiol       Date:  2011-07-01       Impact factor: 4.733

2.  A bio-telemetric device for measurement of left ventricular pressure-volume loops using the admittance technique in conscious, ambulatory rats.

Authors:  Karthik Raghavan; Marc D Feldman; John E Porterfield; Erik R Larson; J Travis Jenkins; Daniel Escobedo; John A Pearce; Jonathan W Valvano
Journal:  Physiol Meas       Date:  2011-05-23       Impact factor: 2.833

3.  Measuring right ventricular function in the normal and hypertensive mouse hearts using admittance-derived pressure-volume loops.

Authors:  Diana M Tabima; Timothy A Hacker; Naomi C Chesler
Journal:  Am J Physiol Heart Circ Physiol       Date:  2010-10-08       Impact factor: 4.733

4.  T-lymphocytes mediate left ventricular fibrillar collagen cross-linking and diastolic dysfunction in mice.

Authors:  Qianli Yu; Randy Vazquez; Sherma Zabadi; Ronald R Watson; Douglas F Larson
Journal:  Matrix Biol       Date:  2010-06-25       Impact factor: 11.583

5.  Myocardial lysyl oxidase regulation of cardiac remodeling in a murine model of diet-induced metabolic syndrome.

Authors:  Sherma Zibadi; Randy Vazquez; Derek Moore; Douglas F Larson; Ronald R Watson
Journal:  Am J Physiol Heart Circ Physiol       Date:  2009-07-10       Impact factor: 4.733

6.  Uncoupled cardiac nitric oxide synthase mediates diastolic dysfunction.

Authors:  Gad A Silberman; Tai-Hwang M Fan; Hong Liu; Zhe Jiao; Hong D Xiao; Joshua D Lovelock; Beth M Boulden; Julian Widder; Scott Fredd; Kenneth E Bernstein; Beata M Wolska; Sergey Dikalov; David G Harrison; Samuel C Dudley
Journal:  Circulation       Date:  2010-01-18       Impact factor: 29.690

7.  Lusitropic effects of dobutamine in young and aged mice in vivo.

Authors:  Emily D Hirleman; Qianli Yu; Douglas F Larson
Journal:  J Extra Corpor Technol       Date:  2008-03

8.  IL-18 induction of osteopontin mediates cardiac fibrosis and diastolic dysfunction in mice.

Authors:  Qianli Yu; Randy Vazquez; Elham Vali Khojeini; Chirag Patel; Raj Venkataramani; Douglas F Larson
Journal:  Am J Physiol Heart Circ Physiol       Date:  2009-05-08       Impact factor: 4.733

9.  Biphasic change of tau (τ) in mice as arterial load acutely increased with phenylephrine injection.

Authors:  Bo Yang; Douglas F Larson; James Ranger-Moore
Journal:  PLoS One       Date:  2013-04-08       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.