Literature DB >> 11904803

Percutaneous endovascular abdominal aortic aneurysm repair.

Elizabeth S Rachel1, Thomas M Bergamini, Edward V Kinney, Matthew T Jung, Hermann W Kaebnick, Richard A Mitchell.   

Abstract

In this prospective, nonrandomized study, we compared outcome with percutaneous femoral artery closure to that with open femoral arteriotomy in 95 patients who underwent endovascular AAA repair. Devices were introduced using 22 Fr and/or 16 Fr sheaths. The 8 Fr/10 Fr Perclose devices (Perclose Inc., Redwood City, CA) were used in an off-label "preclose technique." Thirty-three patients had bilateral open femoral arteriotomies, 44 patients had bilateral attempted percutaneous closure, and 18 patients had open femoral arteriotomy on one side and attempted percutaneous closure on the other side. Percutaneous closure was successful in 85% (47/55) of 16 Fr sheaths and 64% (29/45) of 22 Fr sheaths (p < 0.027). Bilateral percutaneous closure was successful in 63% (28/44) of patients. Conversion to open femoral arteriotomy due to bleeding occurred in 24 of 106 percutaneous attempts. There were no dissections, arterial thromboses, or pseudoaneurysms associated with percutaneous arterial closure. Wound complications were seen in 3.6% (3/84) of open arteriotomies and 0.9% (1/106) of all percutaneous attempts and arterial closures (p > 0.05). Gender, previous femoral access, obesity, and iliac occlusive disease were not predictive of percutaneous failure. Procedural success for percutaneous AAA repair is affected by sheath size. Devices delivered through 16 Fr or smaller sheaths will have successful femoral artery closure rates of at least 85%.

Entities:  

Mesh:

Year:  2002        PMID: 11904803     DOI: 10.1007/s10016-001-0127-3

Source DB:  PubMed          Journal:  Ann Vasc Surg        ISSN: 0890-5096            Impact factor:   1.466


  8 in total

1.  Use of the Perclose ProGlide device with the 9 French Merci retrieval system.

Authors:  Kennith F Layton; J Bradley White; Harry J Cloft; David F Kallmes
Journal:  Neuroradiology       Date:  2006-03-14       Impact factor: 2.804

2.  Ultrasound-guided percutaneous endovascular aneurysm repair success is predicted by access vessel diameter.

Authors:  Rodney P Bensley; Rob Hurks; Zhen Huang; Frank Pomposelli; Allen Hamdan; Mark Wyers; Elliot Chaikof; Marc L Schermerhorn
Journal:  J Vasc Surg       Date:  2012-02-22       Impact factor: 4.268

3.  Percutaneous thoracic endovascular aortic repair is not contraindicated in obese patients.

Authors:  Jason Zakko; Salvatore Scali; Adam W Beck; Charles T Klodell; Thomas M Beaver; Tomas D Martin; Thomas S Huber; Robert J Feezor
Journal:  J Vasc Surg       Date:  2014-05-17       Impact factor: 4.268

4.  A single-centre experience of 200 consecutive unselected patients in percutaneous EVAR.

Authors:  Sergio Petronelli; Maria Teresa Zurlo; Silvia Giambersio; Lucia Danieli; Mariaelena Occhipinti
Journal:  Radiol Med       Date:  2014-04-04       Impact factor: 3.469

Review 5.  Fascia Suture Technique and Suture-mediated Closure Devices: Systematic Review.

Authors:  Georgios Karaolanis; Ioannis D Kostakis; Demetrios Moris; Viktoria-Varvara Palla; Konstantinos G Moulakakis
Journal:  Int J Angiol       Date:  2018-01-22

6.  Percutaneous endovascular abdominal aortic aneurysm repair leads to a reduction in wound complications.

Authors:  C O McDonnell; M V Forlee; J F Dowdall; M-P Colgan; P Madhavan; G D Shanik; D J Moore
Journal:  Ir J Med Sci       Date:  2008-02-02       Impact factor: 1.568

7.  Techniques in endovascular aneurysm repair.

Authors:  Sachin V Phade; Manuel Garcia-Toca; Melina R Kibbe
Journal:  Int J Vasc Med       Date:  2011-10-25

8.  Percutaneous Decannulation for Venoarterial Extracorporeal Membrane Oxygenation Using a Perclose ProGlide Closure Device and a Balloon Catheter Without On-Site Cardiac Surgical Backup.

Authors:  Tomohiro Nakamura; Shinya Murata; Ken Tsuboi; Takeshi Ishida; Shin-Ichi Momomura
Journal:  Cureus       Date:  2022-07-25
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.