A characterization of motion affecting pulse oximetry in 350 patients.

Robert M Tobin1, Jonas A Pologe, Paul B Batchelder.   

Abstract

As part of an oximetry research effort in which plethysmographic data were collected from moving patients, a wide variety of patient motion affecting pulse oximetry was observed and characterized by the clinical incidence, type, severity and duration of patient motion. 350 patients were observed for movement in clinical settings, including ICU, SICU, MICU, PICU, NICU, OR and PACU, at 4 hospitals and on an ambulance. 20% (70) of the patients exhibited motion. Half (35) of the moving patients were instrumented to record oximetric, plethysmographic and/or acceleration information. 31% of NICU infants moved compared to only 7% of adults in ICUs. The most common noisy oximetry signals were caused by motion characterized by extending/flexing (/kicking in infants) and by clenching/pressing/rubbing. In infants, these motion types accounted for 53% and 11% of motion, respectively. Less common infant motion types were patient cares, shifting body position and cough/cry. The most common adult motions were equally divided among extend/flex, clench/press/rub, twitch/shake and transport motion types. Extend/flex motions typically demonstrated high plethysmographic waveform modulation (71.5% maximum) and high acceleration. Clench/press/rub motions typically also had high modulations, but low G-force. With one high-G exception, twitch/shake motions had little or no effect on oximetry readings. Less common adult motion types affecting pulse oximetry included cough/cry, strain/posture, tremors and tap/bump. Most recorded motions were aperiodic and short-lived, 62% lasting less than 10 seconds, only 5% lasting over 1 minute. NICU patients made the longest lasting continuous series of motions, while adults made 86% of the motions lasting a second or less.

Entities:  

Mesh:

Year:  2002        PMID: 11900040

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  6 in total

Review 1.  Skin Pigmentation Influence on Pulse Oximetry Accuracy: A Systematic Review and Bibliometric Analysis.

Authors:  Ana M Cabanas; Macarena Fuentes-Guajardo; Katina Latorre; Dayneri León; Pilar Martín-Escudero
Journal:  Sensors (Basel)       Date:  2022-04-29       Impact factor: 3.847

2.  Quantifying Movement in Preterm Infants Using Photoplethysmography.

Authors:  Ian Zuzarte; Premananda Indic; Dagmar Sternad; David Paydarfar
Journal:  Ann Biomed Eng       Date:  2018-09-25       Impact factor: 3.934

3.  Reduction of motion artifact in pulse oximetry by smoothed pseudo Wigner-Ville distribution.

Authors:  Yong-Sheng Yan; Carmen Cy Poon; Yuan-Ting Zhang
Journal:  J Neuroeng Rehabil       Date:  2005-03-01       Impact factor: 4.262

4.  Lightweight physiologic sensor performance during pre-hospital care delivered by ambulance clinicians.

Authors:  Alasdair J Mort; David Fitzpatrick; Philip M J Wilson; Chris Mellish; Anne Schneider
Journal:  J Clin Monit Comput       Date:  2015-03-25       Impact factor: 2.502

5.  Oxygen Saturation Behavior by Pulse Oximetry in Female Athletes: Breaking Myths.

Authors:  Pilar Martín-Escudero; Ana María Cabanas; Manuel Fuentes-Ferrer; Mercedes Galindo-Canales
Journal:  Biosensors (Basel)       Date:  2021-10-14

6.  Automated Epileptic Seizure Detection Based on Wearable ECG and PPG in a Hospital Environment.

Authors:  Kaat Vandecasteele; Thomas De Cooman; Ying Gu; Evy Cleeren; Kasper Claes; Wim Van Paesschen; Sabine Van Huffel; Borbála Hunyadi
Journal:  Sensors (Basel)       Date:  2017-10-13       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.