Literature DB >> 11896947

Intrapartum fetal head position I: comparison between transvaginal digital examination and transabdominal ultrasound assessment during the active stage of labor.

D M Sherer1, M Miodovnik, K S Bradley, O Langer.   

Abstract

OBJECTIVE: To test the null hypothesis that no correlation exists between transvaginal digital and the gold standard technique of transabdominal suprapubic ultrasound assessments of fetal head position during labor. A secondary objective was to compare the performance of attending physicians vs. senior residents in depicting fetal head position by transvaginal digital examination in comparison with ultrasound, respectively.
METHODS: Consecutive patients in active labor at term with normal singleton cephalic-presenting fetuses were included. All participants had ruptured membranes, cervical dilation > or = 4 cm and fetal head at ischial spine station -2 or lower. Transvaginal sterile digital examinations were performed by either senior residents or attending physicians and followed immediately by transverse suprapubic transabdominal ultrasound assessments. Examiners were blinded to each other's findings. Power-analyses dictated number of subjects required. Statistical analyses included Chi-square, Cohen's Kappa test and logistic regression analysis. P < 0.05 was considered statistically significant.
RESULTS: One hundred and two patients were studied (n = 102). In only 24% of patients (n = 24), transvaginal digital examinations were consistent with ultrasound assessments (P = 0.002, 95% confidence interval, 16-33). Logistic regression revealed that cervical effacement (P = 0.03) and ischial spine station (P = 0.01) significantly affected the accuracy of transvaginal digital examination. Parity, gestational age, combined spinal epidural anesthesia, cervical dilation, birth weight and examiner experience did not significantly affect accuracy of the examination. The accuracy of the transvaginal digital exams was increased to 47% (n = 48) (95% confidence interval, 37-57) when fetal head position at transvaginal digital examination was recorded as correct if reported within +/- 45 degrees of the ultrasound assessment. The rate of agreement between the two assessment methods for attending physicians vs. residents was 58% vs. 33%, respectively (P = 0.02) with the +/- 45 degrees analysis.
CONCLUSIONS: Using ultrasound assessment as the gold standard, our data demonstrate an overall high rate of error (76%) in transvaginal digital determination of fetal head position during active labor, consistent with the null hypothesis. Attending physicians exhibited an almost two-fold higher success rate in depicting correct fetal head position by physical examination vs. residents in the +/- 45 degrees analysis. Intrapartum ultrasound increases the accuracy of fetal head position assessment during active labor and may serve as an educational tool for physicians in training.

Entities:  

Mesh:

Year:  2002        PMID: 11896947     DOI: 10.1046/j.1469-0705.2002.00641.x

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  20 in total

Review 1.  The effectiveness of intrapartum  ultrasonography in assessing cervical dilatation, head station and position: A systematic review and meta-analysis.

Authors:  Yaw Amo Wiafe; Bill Whitehead; Heather Venables; Emmanuel Kweku Nakua
Journal:  Ultrasound       Date:  2016-10-06

2.  Prediction of spontaneous vaginal delivery by transperineal ultrasound performed just after full cervical dilatation is determined.

Authors:  Saeko Kameyama; Akira Sato; Hiroshi Miura; Jin Kumagai; Naoki Sato; Dai Shimizu; Kenichi Makino; Yukihiro Terada
Journal:  J Med Ultrason (2001)       Date:  2015-10-22       Impact factor: 1.314

3.  Intrapartum ultrasound use in clinical practice as a predictor of delivery mode during prolonged second stage of labor.

Authors:  Edi Vaisbuch; Roni Levy; Tamar Katzir; Yoav Brezinov; Ella Khairish; Shira Hadad
Journal:  Arch Gynecol Obstet       Date:  2022-05-16       Impact factor: 2.344

Review 4.  Maternal postures for fetal malposition in labour for improving the health of mothers and their infants.

Authors:  Jennifer A Barrowclough; Luling Lin; Bridget Kool; G Justus Hofmeyr; Caroline A Crowther
Journal:  Cochrane Database Syst Rev       Date:  2022-08-31

5.  Sonographic evaluation in the second stage of labor to improve the assessment of labor progress and its outcome.

Authors:  Lami Yeo; Roberto Romero
Journal:  Ultrasound Obstet Gynecol       Date:  2009-03       Impact factor: 7.299

6.  Study protocol. IDUS - Instrumental delivery & ultrasound: a multi-centre randomised controlled trial of ultrasound assessment of the fetal head position versus standard care as an approach to prevent morbidity at instrumental delivery.

Authors:  Deirdre J Murphy; Gerard Burke; Alan A Montgomery; Meenakshi Ramphul
Journal:  BMC Pregnancy Childbirth       Date:  2012-09-13       Impact factor: 3.007

7.  Extrinsic factors influencing fetal deformations and intrauterine growth restriction.

Authors:  Wendy Moh; John M Graham; Isha Wadhawan; Pedro A Sanchez-Lara
Journal:  J Pregnancy       Date:  2012-07-19

Review 8.  Intrapartum sonography - eccentricity or necessity?

Authors:  Marzena Dębska; Piotr Kretowicz; Romuald Dębski
Journal:  J Ultrason       Date:  2015-06-30

9.  Automatic evaluation of progression angle and fetal head station through intrapartum echographic monitoring.

Authors:  Sergio Casciaro; Francesco Conversano; Ernesto Casciaro; Giulia Soloperto; Emanuele Perrone; Gian Carlo Di Renzo; Antonio Perrone
Journal:  Comput Math Methods Med       Date:  2013-09-09       Impact factor: 2.238

10.  Fetal Head Position during the First Stage of Labor: Comparison between Vaginal Examination and Transabdominal Ultrasound.

Authors:  Jyothi Shetty; Vinod Aahir; Deeksha Pandey; Prashanth Adiga; Asha Kamath
Journal:  ISRN Obstet Gynecol       Date:  2014-03-27
View more