Literature DB >> 11891980

Effects of iodinated contrast and field strength on gadolinium enhancement: implications for direct MR arthrography.

Douglas D Montgomery1, William B Morrison, Mark E Schweitzer, Dominik Weishaupt, Lawrence Dougherty.   

Abstract

PURPOSE: To optimize direct magnetic resonance (MR) arthrography by determining the effect of dilution of gadolinium in iodinated contrast, saline, or albumin on T1-weighted, T2-weighted, and gradient-recalled echo (GRE) images, and the effect of scanner field strength.
MATERIALS AND METHODS: Gadopentetate dimeglumine was diluted into normal saline, albumin, or iodinated contrast (0.625 mmol/liter to 40 mmol/liter). Samples were scanned at 1.5T and 0.2T. Signal intensity was measured using T1-weighted spin-echo (SE), T2-weighted SE, and two- and three-dimensional GRE (20 degrees-75 degrees flip angle) sequences. Graphical analysis of signal intensity vs. gadolinium concentration was performed.
RESULTS: Albumin had no effect on gadolinium contrast. Dilution of gadolinium in iodinated contrast decreased signal intensity on all sequences compared to samples of identical concentration diluted in saline at both 1.5T and 0.2T: with a 2 mmol/liter gadolinium solution at 1.5T, signal was decreased by 26.1% on T1-weighted images, 31.7% on GRE20 images, and 28.9% on GRE45 images, and the T2 value decreased by 71.1%; at 0.2T, signal was decreased by 23.5% on T1-weighted images. On all sequences, the peak signal shifted to the left (lower gadolinium concentration) when diluted in iodinated contrast. Peak signal was also seen at different gadolinium concentrations on different sequences and field strength: at 1.5T, peak in saline/iodine was 2.5/0.625 mmol/liter on T1-weighted images, and 2.5/1.25 mmol/liter on GRE20 and GRE45 sequences. At 0.2T, peak in saline/iodine was 0.625-2.5/1.25 mmol/liter on T1-weighted images, 0.625-2.5/1.25 on GRE45 images, 2.5-10.0/1.25-5.0 mmol/liter on GRE65 images, and 1.25-5.0/0.625-1.25 mmol/liter on GRE75 images.
CONCLUSION: Dilution of gadolinium in iodinated contrast results in decreased signal on T1-weighted, T2-weighted, and GRE images compared to dilution in saline or albuminfor both 1.5-T and 0.2-T scanners; if gadolinium is diluted in iodinated contrast for MR arthrography, a lower concentration should be used because the peak is shifted to the left. The use of iodinated contrast should be minimized, as it may diminish enhancement and lower the sensitivity and specificity of MR arthrography. Optimal gadolinium concentration for MR arthrography is dependent on scanner field strength and a broader range of gadolinium concentration can be used to provide maximal signal at low field strength.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11891980     DOI: 10.1002/jmri.10065

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  7 in total

Review 1.  [Combined use of contrast media containing iodine and gadolinium for imaging and intervention : A hitherto widely ignored topic in radiological practice].

Authors:  W Golder
Journal:  Radiologe       Date:  2012-02       Impact factor: 0.635

2.  Ultrasound guidance to perform intra-articular injection of gadolinium-based contrast material for magnetic resonance arthrography as an alternative to fluoroscopy: the time is now.

Authors:  Carmelo Messina; Giuseppe Banfi; Alberto Aliprandi; Giovanni Mauri; Francesco Secchi; Francesco Sardanelli; Luca Maria Sconfienza
Journal:  Eur Radiol       Date:  2015-08-08       Impact factor: 5.315

Review 3.  Muskuloskeletal MR imaging at 3.0 T: current status and future perspectives.

Authors:  Nicolae Bolog; Daniel Nanz; Dominik Weishaupt
Journal:  Eur Radiol       Date:  2006-03-16       Impact factor: 5.315

Review 4.  MR arthrography made simple: indications and techniques.

Authors:  John D MacKenzie
Journal:  Pediatr Radiol       Date:  2008-05

5.  Optimization of the contrast mixture ratio for simultaneous direct MR and CT arthrography: an in vitro study.

Authors:  Ja Young Choi; Heung Sik Kang; Sung Hwan Hong; Joon Woo Lee; Na Ra Kim; Woo Sun Jun; Sung Gyu Moon; Jung Ah Choi
Journal:  Korean J Radiol       Date:  2008 Nov-Dec       Impact factor: 3.500

6.  Erroneous intra-articular injection of gadolinium solution at 0.5 mol/l concentration: a case report.

Authors:  Eugenio A Genovese; Elena Bertolotti; Carlo Fugazzola
Journal:  Cases J       Date:  2009-12-14

7.  Effects of iodinated contrast agent, xylocaine and gadolinium concentration on the signal emitted in magnetic resonance arthrography: a samples study.

Authors:  Yvana Lopes Pinheiro da Silva; Rita Zanlorensi Visneck Costa; Kátia Elisa Prus Pinho; Ricardo Rabello Ferreira; Sueliton Miyamoto Schuindt
Journal:  Radiol Bras       Date:  2015 Mar-Apr
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.