Transscleral optical coherence tomography--an experimental study in ex-vivo human eyes.

Hans Hoerauf1, Jörg Winkler, Christian Scholz, Christopher Wirbelauer, Roswitha S Gordes, Peter Koch, Ralf Engelhardt, Horst Laqua, Reginald Birngruber.   

Abstract

BACKGROUND AND
OBJECTIVE: To evaluate the potentials of a 1310-nm optical coherence tomography (OCT) system to penetrate the highly backscattering sclera in enucleated human eyes and provide visualization of intraocular structures by transscleral imaging. STUDY DESIGN/
MATERIALS AND METHODS: OCT-images were generated by an experimental prototype (Medical Laser Center, Lübeck, Germany) using a superluminescence diode with a wavelength of 1310 nm. OCT-images were taken from two enucleated human eyes using 100-200 axial scans with 60 Hz line scan frequency and compared to subsequent histologic sections.
RESULTS: Transscleral OCT allowed penetration of the sclera and the anterior chamber angle could be completely identified. Some change within the anterior eye segment could be demonstrated with high accuracy. Additionally, limited demonstration of the ciliary body region was achieved. Due to limited signal intensity no detailed imaging of the pars plana and pars plicata region was possible. However, more posterior measurements allowed transscleral visualization of a retinal detachment.
CONCLUSIONS: OCT using lightsources with a wavelength longer than that used in conventional OCT provides a promising imaging technique at high resolution allowing transscleral imaging of the anterior eye segment. Copyright 2002 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2002        PMID: 11891740     DOI: 10.1002/lsm.10031

Source DB:  PubMed          Journal:  Lasers Surg Med        ISSN: 0196-8092            Impact factor:   4.025


  5 in total

1.  [Reproducibility of goniometry with slitlamp-adapted optical coherence tomography].

Authors:  A Karandish; C Wirbelauer; H Häberle; D T Pham
Journal:  Ophthalmologe       Date:  2004-06       Impact factor: 1.059

2.  Optical coherence tomography of the Ex-PRESS miniature glaucoma implant.

Authors:  F D Verbraak; D M de Bruin; M Sulak; L A M S de Jong; M Aalders; D J Faber; T G van Leeuwen
Journal:  Lasers Med Sci       Date:  2005-04-28       Impact factor: 3.161

3.  Optical coherence tomography of the anterior segment in secondary glaucoma with corneal opacity after penetrating keratoplasty.

Authors:  Farnaz Memarzadeh; Yan Li; Brian A Francis; Ronald E Smith; Julie Gutmark; David Huang
Journal:  Br J Ophthalmol       Date:  2006-09-14       Impact factor: 4.638

4.  Real-time imaging of transscleral diode laser cyclophotocoagulation by optical coherence tomography.

Authors:  H Hoerauf; M Müller; G Hüttmann; C Winter; T Schlote
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-09-28       Impact factor: 3.117

5.  Optical coherence tomography in malignant glaucoma following filtration surgery.

Authors:  C Wirbelauer; A Karandish; H Häberle; D T Pham
Journal:  Br J Ophthalmol       Date:  2003-08       Impact factor: 4.638