Literature DB >> 11890177

The detection and identification of quaternary nitrogen muscle relaxants in biological fluids and tissues by ion-trap LC-ESI-MS.

C H M Kerskes1, K J Lusthof, P G M Zweipfenning, J P Franke.   

Abstract

Quaternary nitrogen muscle relaxants pancuronium, rocuronium, vecuronium, gallamine, suxamethonium, mivacurium, and atracurium and its metabolites were extracted from whole blood and other biological fluids and tissues by using a solid-phase extraction procedure. The extracts were examined by using high-performance liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS). The drugs were separated on a ODS column in a gradient of ammonium acetate buffer (pH 5.0) and acetonitrile. Full-scan mass spectra of the compounds showed molecular ions, and MS-MS spectra showed fragments typical of the particular compounds. LC-ESI-MS allowed an unequivocal differentiation of all muscle relaxants involved. The method was applied in a case of rocuronium and suxamethonium administration in a Caesarian section and in a case of intoxication by pancuronium injection. In both cases, the administered drugs could be detected and identified in the supplied samples.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11890177     DOI: 10.1093/jat/26.1.29

Source DB:  PubMed          Journal:  J Anal Toxicol        ISSN: 0146-4760            Impact factor:   3.367


  4 in total

1.  An analytical strategy for quaternary ammonium neuromuscular blocking agents in a forensic setting using LC-MS/MS on a tandem quadrupole/time-of-flight instrument.

Authors:  Kevin D Ballard; William E Vickery; Loan T Nguyen; Francis X Diamond; Fredric Rieders
Journal:  J Am Soc Mass Spectrom       Date:  2006-08-02       Impact factor: 3.109

2.  Fall downstairs: accident, homicide or natural death?

Authors:  Burkhard Madea; Reinhard Dettmeyer; Frank Musshoff
Journal:  Forensic Sci Med Pathol       Date:  2007-10-02       Impact factor: 2.007

3.  Stability indicating liquid chromatography method for the analysis of Vecuronium bromide: study of the degradation profile.

Authors:  Mohamed K Abd Elrahman; Ola M El Houssini; Diana K Fahem; Hala E Zaazaa
Journal:  Heliyon       Date:  2020-03-16

4.  [Simultaneous determination of three quaternary ammonium muscle relaxants in blood by high performance liquid chromatography-tandem mass spectrometry].

Authors:  Yongpeng Huang; Hui Tang; Yunyang Song; Bo Chen; Hui Zhong
Journal:  Se Pu       Date:  2021-07-08
  4 in total