Literature DB >> 11888821

Location, size and morphological characteristics of left atrial thrombi as assessed by echocardiography in patients with rheumatic mitral valve disease.

C Kaymaz1, N Ozdemir, C Kirma, M Sişmanoglu, B Daglar, M Ozkan.   

Abstract

AIMS: This study aimed to assess the use of transthoracic and transoesophageal echocardiography in diagnosing the thrombi located in the left atrium and/or left atrial appendage in patients with rheumatic mitral valve disease, and to investigate the characteristics of thrombi in comparison to intraoperative findings. METHODS AND
RESULTS: The study group was comprised of 474 patients who underwent transthoracic and transoesophageal echocardiography prior to mitral valve surgery. Location, thickness and morphological characteristics of thrombi were determined by transoesophageal echocardiography. Intraoperative assessment disclosed left atrial thrombi in 105 patients. Thickness of thrombi < or = 1cm, and thrombi confined to left atrial appendage were associated with false-negative results by transthoracic echocardiography. However, diameter and morphological characteristics of thrombi, left atrial and left atrial appendage size, and the presence of the spontaneous echo contrast were not associated with the diagnosis of thrombi by transthoracic echocardiography. For overall left atrial thrombi, sensitivity and specificity of transthoracic echocardiography were 32%, and 94%, respectively. Sensitivity and specificity of transoesophageal echocardiography for thrombi in the left atrial appendage were 98%, and 98%, for thrombi in the main left atrial cavity were 81%, and 99%, and for thrombi located in both left atrium and appendage cavities were 100%, and 100%, respectively.
CONCLUSION: In patients with rheumatic mitral valve disease, detection of left atrial thrombi by transthoracic echocardiography seems to be determined by thickness and location of thrombi. The multilobed structure of the left atrial appendage and artifacts over posterior wall of the left atrium may still prevent precise diagnosis even with transoesophageal echocardiography.

Entities:  

Mesh:

Year:  2001        PMID: 11888821     DOI: 10.1053/euje.2001.0093

Source DB:  PubMed          Journal:  Eur J Echocardiogr        ISSN: 1532-2114


  5 in total

1.  Cost and utility in the diagnostic evaluation of stroke.

Authors:  James F Burke
Journal:  Continuum (Minneap Minn)       Date:  2014-04

2.  Percutaneous transluminal mitral commissurotomy for rheumatic mitral stenosis in a 5-year-old child.

Authors:  Maad Ullah; Mehboob Sultan; Hajira Akbar; Nadeem Sadiq
Journal:  Pediatr Cardiol       Date:  2012-02-15       Impact factor: 1.655

3.  A track made by organized thrombus after catheter fragment removal mimicking a remnant catheter in the popliteal artery.

Authors:  Tae-Hoon Kim; Michael Azrin; Juyong Lee
Journal:  J Vasc Surg Cases Innov Tech       Date:  2017-07-24

Review 4.  Percutaneous Left Atrial Appendage Closure: is there a Role in Valvular Atrial Fibrillation.

Authors:  Chetan Huded; Amar Krishnaswamy; Samir Kapadia
Journal:  J Atr Fibrillation       Date:  2017-02-28

5.  Reccurent thrombus in the gigantic left atrium during effective anticoagulant therapy: case report.

Authors:  Lucia Masarova; Jan Novak; Martin Pesl; Jiri Ondrasek; Jiri Semenka; Eva Simarova; Roman Panovsky
Journal:  BMC Cardiovasc Disord       Date:  2020-02-21       Impact factor: 2.298

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.