Biologic and mechanical stability of single-tooth implants: 4- to 7-year follow-up.

M R Norton1.   

Abstract

BACKGROUND: Single-tooth implants have been reported to achieve a high level of surgical and prosthetic success. However, close inspection of the literature reveals a paucity of data on the follow-up of single-tooth implants in function for 5 years or more. Since unsplinted implants may be considered to be subject to greater functional stresses, there is a need to report on the long-term biologic and mechanical integrity of such implant-supported restorations.
PURPOSE: To report on the long-term follow-up of single-tooth implants, restored and in function for 4 to 7 years.
MATERIALS AND METHODS: Twenty-seven Astra Tech single-tooth implants were subject to a clinical audit to evaluate implant and prosthetic success as well as response of both hard and soft tissues over a 1- to 4-year follow-up. This current report presents data on the biologic and mechanical integrity of 23 of these single-tooth implants, which have been in function for up to 7 years (mean, 63 mo). Data are provided with respect to implant survival, maintenance of marginal bone levels, soft-tissue health, and the recording of any adverse events, including prosthetic complications.
RESULTS: Only 14 implants in 13 patients were available for review, with no failures for this group of implants. One patient from the original group, who was lost to follow-up, was known to have suffered an implant failure. Furthermore, in accordance with established criteria, the remaining 13 implants that are not included in this report must at this time also be considered as potential failures. As such, the best-case scenario would be a 95.6% success rate for the 23 implants included in this review and the worst-case scenario would be a 60.8% success rate. Mean marginal bone loss measured 0.49 mm mesially and 0.76 mm distally, with a frequency of bone loss of 50%. Soft tissues were clinically healthy. There were few adverse events, with only one case of abutment screw loosening, detected at the 6-year review. In addition, crown decementation was recorded three times in two patients.
CONCLUSIONS: It can be concluded that the Astra Tech single-tooth implant can achieve long-term biologic and mechanical stability when used to restore single missing teeth, over the long-term.

Entities:  

Mesh:

Year:  2001        PMID: 11887658     DOI: 10.1111/j.1708-8208.2001.tb00143.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  6 in total

1.  Use of separate single-tooth implant restorations to replace two or more consecutive posterior teeth: a prospective cohort study for up to 1 year.

Authors:  Min-Jung Kwon; In-Sung Yeo; Young-Kyun Kim; Yang-Jin Yi; Jae-Ho Yang
Journal:  J Adv Prosthodont       Date:  2010-06-30       Impact factor: 1.904

2.  Implant supported prosthesis in a patient with progeria: case report.

Authors:  Gözlem Ceylan; Nergiz Yilmaz; Ozgün Senyurt; Göknil Ergün Kunt
Journal:  Bosn J Basic Med Sci       Date:  2009-08       Impact factor: 3.363

3.  Marginal bone response of implants with platform switching and non-platform switching abutments in posterior healed sites: a 1-year prospective study.

Authors:  Yun-Chi Wang; Joseph Y K Kan; Kitichai Rungcharassaeng; Phillip Roe; Jaime L Lozada
Journal:  Clin Oral Implants Res       Date:  2014-01-03       Impact factor: 5.977

4.  Effect of cyclic load on vertical misfit of prefabricated and cast implant single abutment.

Authors:  Rudys Rodolfo de Jesus Tavarez; Wellington Cardoso Bonachela; Anuar Antônio Xible
Journal:  J Appl Oral Sci       Date:  2011 Jan-Feb       Impact factor: 2.698

Review 5.  Dealing with dental implant failures.

Authors:  Liran Levin
Journal:  J Appl Oral Sci       Date:  2008 May-Jun       Impact factor: 2.698

6.  Short-term improvement of masticatory function after implant restoration.

Authors:  Si-Mook Kang; Sang-Soo Lee; Ho-Keun Kwon; Baek-Il Kim
Journal:  J Periodontal Implant Sci       Date:  2015-12-28       Impact factor: 2.614

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.