European Concerted Action on Anticoagulation (ECAA): multicentre international sensitivity index calibration of two types of point-of-care prothrombin time monitor systems.

L Poller1, M Keown, N Chauhan, A M H P van Den Besselaar, A Tripodi, J Jespersen, C Shiach, M H Horellou, D Dias, N Egberg, J A Iriarte, I Kontopoulou-Griva, B Otridge.   

Abstract

A multicentre modified World Health Organization (WHO)-type international sensitivity index (ISI) calibration has been performed at 10 European Concerted Action on Anticoagulation (ECAA) national laboratories using non-citrated whole-blood on two point-of-care test (POCT) prothrombin time (PT) monitor systems, CoaguChek Mini and TAS PT-NC, using single lots of test cards/strips. The relevant species (human and rabbit) WHO international reference preparations (IRPs) were tested with the manual PT technique on citrated plasma from the same blood donations. The ISI was calculated from the slope of the orthogonal regression line relating log PT (POCT) to log PT (IRP). The mean ISI of the CoaguChek Mini system was 1.75 and 1.13 with the prothrombin time non-citrated Thrombolytic Assessment System (TAS PT-NC). With the CoaguChek Mini system, seven out of 10 calibrations exceeded the current 3% WHO recommended limit for the coefficient of variation (CV) of the slope with conventional PT testing, whereas with the TAS PT-NC system, it was eight out of 10. All the POCT calibrations had a CV of the slope <5%. It is suggested that this level of precision be adopted as the limit of acceptability of calibration of these monitor systems. In these circumstances, the modified WHO-type ISI calibration appeared to be satisfactory for the POCT whole-blood monitors.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11886390     DOI: 10.1046/j.0007-1048.2002.03361.x

Source DB:  PubMed          Journal:  Br J Haematol        ISSN: 0007-1048            Impact factor:   6.998


  4 in total

1.  European Concerted Action on Anticoagulation (ECAA). An assessment of lyophilised plasmas for ISI calibration of CoaguChek and TAS whole blood prothrombin time monitors.

Authors:  L Poller; M Keown; N Chauhan; A M H P van den Besselaar; A Tripodi; C Shiach; J Jespersen
Journal:  J Clin Pathol       Date:  2003-02       Impact factor: 3.411

2.  European Concerted Action on Anticoagulation. A multicentre calibration study of WHO international reference preparations for thromboplastin, rabbit (RBT/90) and human (rTF/95).

Authors:  L Poller; M Keown; N Chauhan; A M H P van den Besselaar; A Tripodi; C Shiach; J Jespersen
Journal:  J Clin Pathol       Date:  2005-06       Impact factor: 3.411

Review 3.  Oral anticoagulant therapy: Antithrombotic Therapy and Prevention of Thrombosis, 9th ed: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines.

Authors:  Walter Ageno; Alexander S Gallus; Ann Wittkowsky; Mark Crowther; Elaine M Hylek; Gualtiero Palareti
Journal:  Chest       Date:  2012-02       Impact factor: 9.410

4.  Reliability of international normalised ratios from two point of care test systems: comparison with conventional methods.

Authors:  Leon Poller; Michelle Keown; Nikhil Chauhan; Anton M H P van den Besselaar; Armando Tripodi; Caroline Shiach; Jorgen Jespersen
Journal:  BMJ       Date:  2003-07-05
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.