Literature DB >> 11886193

The effect of 10% povidone--iodine solution on contaminated bone allografts.

J Soyer1, M Rouil, O Castel.   

Abstract

The aim of this study was to determine the efficacy of 10% povidone--iodine solution for the decontamination of bone allografts. Bone samples were prepared and tested for sterility using a femoral head removed at the time of primary hip replacement. They were contaminated by a suspension of Staphylococcus epidermidis and ground to measure the quantity of micro-organism attached to the bone. Two levels of contamination were used (1 x 10(3) vs. 1 x 10(4)CFU/mL) to check the efficiency of our method of measurement. Samples of the two groups were decontaminated with 10% povidone--iodine solution using different exposure times. Before decontamination, the count of bacteria attached to the bone was proportional to the bacterial concentration of the contaminating solution. The microbiocidal activity of 10% povidone--iodine solution was the same in both groups. The decontamination time was proportional to the bacterial concentration of the contaminating solution. The results of this preliminary study suggest that a 10% povidone--iodine solution can decontaminate inoculated bone grafts, but a sufficient time of exposure according to the level of contamination must be allowed. Copyright 2002 The Hospital Infection Society.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11886193     DOI: 10.1053/jhin.2001.1153

Source DB:  PubMed          Journal:  J Hosp Infect        ISSN: 0195-6701            Impact factor:   3.926


  7 in total

1.  Are Dropped Bone Grafts Safe to be Re-used? - An Experimental Study Comparing Efficacy of Chlorhexidine, Povidone-Iodine and Alcohol.

Authors:  M F Mat-Salleh; A N Sadagatullah; M Y Ibrahim; I Abdul-Aziz; W A Wan-Abdullah; N Maning; M N Md-Hassan; M R Ab-Rashid
Journal:  Malays Orthop J       Date:  2021-07

Review 2.  Comparison of the Sterilization Efficiency of 3 Disinfectants for Dropped Anterior Cruciate Ligament Grafts: A Systematic Review and Meta-analysis.

Authors:  Xianyue Shen; Yanguo Qin; Jianlin Zuo; Tong Liu; Jianlin Xiao
Journal:  Orthop J Sports Med       Date:  2021-05-10

3.  Use of polyvinylpyrrolidone-iodine solution for sterilisation and preservation improves mechanical properties and osteogenesis of allografts.

Authors:  Yantao Zhao; Xiantong Hu; Zhonghai Li; Fuli Wang; Yang Xia; Shuxun Hou; Hongbin Zhong; Feimin Zhang; Ning Gu
Journal:  Sci Rep       Date:  2016-12-09       Impact factor: 4.379

4.  The mid-long term results of reconstructional cage and morselized allografts combined application for the Paprosky type III acetabular bone defects in revision hip arthroplasty.

Authors:  Qiang Xiao; Haoyang Wang; Kai Zhou; Duan Wang; Tingxian Ling; Fuxing Pei; Zongke Zhou
Journal:  BMC Musculoskelet Disord       Date:  2019-11-07       Impact factor: 2.362

5.  Effect of three different sterilizing solutions on the contaminated bone: an experimental study in the rabbit.

Authors:  Hamidreza Yazdi; Mehdi Ramezan Shirazi; Omid Momen Shouli; Farzad Yazdi; Alireza Moslem
Journal:  Med J Islam Repub Iran       Date:  2012-08

6.  Contaminated osteochondral plugs: effect of different sterilizing solutions: an experimental study in the rabbit.

Authors:  Hamidreza Yazdi; Mehdi Ramezan Shirazi; Gholamreza Shafiee; Masoumeh Shahcheraghi
Journal:  Med J Islam Repub Iran       Date:  2012-11

7.  Management of contaminated autologous grafts in plastic surgery.

Authors:  Robert F Centeno; Ankit R Desai; Marla E Watson
Journal:  Eplasty       Date:  2008-04-22
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.