Literature DB >> 11885678

Clutter filter design for ultrasound color flow imaging.

Steinar Bjaerum1, Hans Torp, Kjell Kristoffersen.   

Abstract

For ultrasound color flow images with high quality, it is important to suppress the clutter signals originating from stationary and slowly moving tissue sufficiently. Without sufficient clutter rejection, low velocity blood flow cannot be measured, and estimates of higher velocities will have a large bias. The small number of samples available (8 to 16) makes clutter filtering in color flow imaging a challenging problem. In this paper, we review and analyze three classes of filters: finite impulse response (FIR), infinite impulse response (IIR), and regression filters. The quality of the filters was assessed based on the frequency response, as well as on the bias and variance of a mean blood velocity estimator using an autocorrelation technique. For FIR filters, the frequency response was improved by allowing a non-linear phase response. By estimating the mean blood flow velocity from two vectors filtered in the forward and backward direction, respectively, the standard deviation was significantly lower with a minimum phase filter than with a linear phase filter. For IIR filters applied to short signals, the transient part of the output signal is important. We analyzed zero, step, and projection initialization, and found that projection initialization gave the best filters. For regression filters, polynomial basis functions provide effective clutter suppression. The best filters from each of the three classes gave comparable bias and variance of the mean blood velocity estimates. However, polynomial regression filters and projection-initialized IIR filters had a slightly better frequency response than could be obtained with FIR filters.

Mesh:

Year:  2002        PMID: 11885678     DOI: 10.1109/58.985705

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  21 in total

1.  Adaptive clutter rejection filtering in ultrasonic strain-flow imaging.

Authors:  Christian Kargel; Gernot Höbenreich; Birgit Trummer; Michael F Insana
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-07       Impact factor: 2.725

2.  A study of the adult zebrafish ventricular function by retrospective Doppler-gated ultrahigh-frame-rate echocardiography.

Authors:  Ting-Yu Liu; Po-Yang Lee; Chih-Chung Huang; Lei Sun; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-09       Impact factor: 2.725

3.  Doppler OCT clutter rejection using variance minimization and offset extrapolation.

Authors:  Adil Akif; Konrad Walek; Collin Polucha; Jonghwan Lee
Journal:  Biomed Opt Express       Date:  2018-10-10       Impact factor: 3.732

4.  Coherent flow power Doppler (CFPD): flow detection using spatial coherence beamforming.

Authors:  You Leo Li; Jeremy J Dahl
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-06       Impact factor: 2.725

5.  Ultrasonic colour Doppler imaging.

Authors:  David H Evans; Jørgen Arendt Jensen; Michael Bachmann Nielsen
Journal:  Interface Focus       Date:  2011-05-06       Impact factor: 3.906

6.  Visualization of Small-Diameter Vessels by Reduction of Incoherent Reverberation With Coherent Flow Power Doppler.

Authors:  You Leo Li; Dongwoon Hyun; Lotfi Abou-Elkacem; Juergen Karl Willmann; Jeremy J Dahl
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-11       Impact factor: 2.725

7.  Combining Slow Flow Techniques With Adaptive Demodulation for Improved Perfusion Ultrasound Imaging Without Contrast.

Authors:  Jaime Tierney; Kristy Walsh; Helen Griffith; Jennifer Baker; Daniel B Brown; Brett Byram
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-02-07       Impact factor: 2.725

8.  A single-ensemble-based hybrid approach to clutter rejection combining bilinear Hankel with regression.

Authors:  Zhiyuan Shen; Naizhang Feng; Chin-Hui Lee
Journal:  J Med Ultrason (2001)       Date:  2012-10-16       Impact factor: 1.314

9.  Adaptive Clutter Demodulation for Non-Contrast Ultrasound Perfusion Imaging.

Authors:  Jaime Tierney; Crystal Coolbaugh; Theodore Towse; Brett Byram
Journal:  IEEE Trans Med Imaging       Date:  2017-06-13       Impact factor: 10.048

10.  Quantitative assessment of the magnitude, impact and spatial extent of ultrasonic clutter.

Authors:  Muyinatu A Lediju; Michael J Pihl; Jeremy J Dahl; Gregg E Trahey
Journal:  Ultrason Imaging       Date:  2008-07       Impact factor: 1.578

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.