Literature DB >> 11885352

A pilot study of three methods for the reduction of bacterial contamination of dental unit water systems in routine use.

Lutz Jatzwauk1, Bernd Reitemeier.   

Abstract

Three different methods for minimizing the bacterial contamination of the water system in a SIRONA C2 type dental unit were investigated sequentially. Without any decontamination method, water from the hand piece, air-water-jet and mouthwash were continuously contaminated by 10(3) to 10(5) colony forming units (cfu) of aerobic mesophilic bacteria per milliliter. A reduction to below 100 cfu/ml was achieved by continuous adding of a chemical microbicide based on hydrogen peroxide and silver ions. However, this was only possible after rinsing the system thoroughly for at least two minutes after interruptions of the treatment. Long-lasting low counts of below 100/ml were obtained by means of an in-line bacteria filter, in connection with the provision of a thermo-chemical or thermal decontamination of the water pipes and hand pieces after the filter. The electrolyte release of chlorine from the dental unit tap water by anodic oxidation without addition of any chemical disinfectant also resulted in continuously low colony numbers of the water. In this case, regular decontamination of the end parts of the pipes and hand pieces was not necessary.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11885352     DOI: 10.1078/1438-4639-00120

Source DB:  PubMed          Journal:  Int J Hyg Environ Health        ISSN: 1438-4639            Impact factor:   5.840


  4 in total

1.  Evaluation of bacterial contamination of dental unit waterlines and use of a newly designed measurement device to assess retraction of a dental chair unit.

Authors:  Xue-Yue Ji; Chun-Nan Fei; Ying Zhang; Wei Zhang; Jun Liu; Jie Dong
Journal:  Int Dent J       Date:  2016-03-21       Impact factor: 2.607

2.  Impact of a risk management plan on Legionella contamination of dental unit water.

Authors:  Erica Leoni; Laura Dallolio; Francesca Stagni; Tiziana Sanna; Giovanni D'Alessandro; Gabriela Piana
Journal:  Int J Environ Res Public Health       Date:  2015-02-23       Impact factor: 3.390

3.  Disinfection of dental unit water line using aloe vera: in vitro study.

Authors:  Sonia Pareek; Anup Nagaraj; Prateek Sharma; Mansi Atri; Satinder Walia; Shravani Naidu; Asif Yousuf
Journal:  Int J Dent       Date:  2013-09-08

4.  Effect of different disinfection protocols on microbial and biofilm contamination of dental unit waterlines in community dental practices.

Authors:  Laura Dallolio; Amalia Scuderi; Maria S Rini; Sabrina Valente; Patrizia Farruggia; Maria A Bucci Sabattini; Gianandrea Pasquinelli; Anna Acacci; Greta Roncarati; Erica Leoni
Journal:  Int J Environ Res Public Health       Date:  2014-02-18       Impact factor: 3.390