Literature DB >> 11884490

Quantification of lymphatic function for investigation of lymphedema: depot clearance and rate of appearance of soluble macromolecules in blood.

Simon J Pain1, R Steven Nicholas, Robert W Barber, James R Ballinger, Arnie D Purushotham, Peter S Mortimer, A Michael Peters.   

Abstract

UNLABELLED: The object of this study was to develop a new technique for the quantitative measurement of lymphatic function. The rate of clearance of radiolabeled protein from a subcutaneous depot is supplemented by measurement of the appearance of the protein in venous blood. This initial study was performed on normal arms, with a view to subsequent clinical application such as in the investigation of women with breast cancer--related lymphedema (BCRL).
METHODS: Fourteen healthy volunteers (12 women, 2 men) and 8 women awaiting surgery for breast cancer were recruited for the study. Each received subcutaneous depot injection of protein solution in the second dorsal web space of each hand, labeled with (111)In on one side and with (99m)Tc on the other side. Human serum albumin (HSA) was the protein used in the first 8 subjects and human polyclonal immunoglobulin G (HIgG) was used thereafter. The activity at each depot was measured at regular intervals using a collimated sodium iodide scintillation detector, and the activity in venous blood sampled from both arms was measured in an automatic sample counter.
RESULTS: (99m)Tc-HSA cleared from the depot consistently faster than (111)In-HSA (P = 0.001). The proportions of radionuclide remaining bound to protein in venous blood were higher for (99m)Tc than for (111)In. HIgG displayed improved labeling stability for both nuclides, reflected in equal rates of clearance. Blood activity rose steadily after an early latent phase and for HIgG correlated strongly with the rate of clearance from the depot (P < 0.001). Marked variation between individuals was observed.
CONCLUSION: A dual-isotope technique relies on identical behavior of the 2 radiopharmaceuticals used. This study shows that this is the case with respect to HIgG but not HSA. (99m)Tc-HSA cleared faster than (111)In-HSA and yet displayed better in vivo labeling stability. We conclude that (111)In dissociates from HSA in the depot but then becomes locally bound. Using HIgG, a close correlation was observed between the rates of clearance from the depot and the appearance in venous blood. This finding suggests that HIgG would be a suitable marker for subsequent dual-isotope studies on women with BCRL.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11884490

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  7 in total

1.  Drug elimination kinetics following subconjunctival injection using dynamic contrast-enhanced magnetic resonance imaging.

Authors:  Stephanie H Kim; Karl G Csaky; Nam Sun Wang; Robert J Lutz
Journal:  Pharm Res       Date:  2007-08-03       Impact factor: 4.200

2.  Quantitative measurement of lymphatic function in mice by noninvasive near-infrared imaging of a peripheral vein.

Authors:  Steven T Proulx; Qiaoli Ma; Diana Andina; Jean-Christophe Leroux; Michael Detmar
Journal:  JCI Insight       Date:  2017-01-12

3.  New approaches to lymphatic imaging.

Authors:  Richard T Lucarelli; Mikako Ogawa; Nobuyuki Kosaka; Baris Turkbey; Hisataka Kobayashi; Peter L Choyke
Journal:  Lymphat Res Biol       Date:  2009-12       Impact factor: 2.589

Review 4.  Exercise and the lymphatic system: implications for breast-cancer survivors.

Authors:  Kirstin Lane; Dan Worsley; Don McKenzie
Journal:  Sports Med       Date:  2005       Impact factor: 11.136

5.  Finding an optimal method for imaging lymphatic vessels of the upper limb.

Authors:  Susan O'Mahony; Sarah L Rose; Alison J Chilvers; James R Ballinger; Chandra K Solanki; Robert W Barber; Peter S Mortimer; Arnie D Purushotham; A Michael Peters
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-01-14       Impact factor: 9.236

6.  Human lymphatic pumping measured in healthy and lymphoedematous arms by lymphatic congestion lymphoscintigraphy.

Authors:  S Modi; A W B Stanton; W E Svensson; A M Peters; P S Mortimer; J R Levick
Journal:  J Physiol       Date:  2007-06-14       Impact factor: 5.182

7.  Side-to-side symmetry of radioprotein transfer from tissue space to systemic vasculature following subcutaneous injection in normal subjects and patients with breast cancer.

Authors:  Simon J Pain; Robert W Barber; James R Ballinger; Chandra K Solanki; Susan O'Mahony; Peter S Mortimer; Arnie Purushotham; A Michael Peters
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-03-22       Impact factor: 9.236

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.