Literature DB >> 11882792

Dynamic ventilation (3)He-magnetic resonance imaging with lung motion correction: gas flow distribution analysis.

Klaus Kurt Gast1, Michael Ulrich Puderbach, Ignacio Rodriguez, Balthasar Eberle, Klaus Markstaller, Alexander Thomas Hanke, Joerg Schmiedeskamp, Norbert Weiler, Jana Lill, Wolfgang G Schreiber, Manfred Thelen, Hans-Ulrich Kauczor.   

Abstract

RATIONALE AND
OBJECTIVES: Software was developed to correct for lung motion to improve the description of hyperpolarized (3)He gas distribution in the lung.
METHODS: Five volunteers were studied by dynamic ventilation (3)He-MRI using an ultrafast FLASH 2D sequence with a temporal resolution of 128 milliseconds. Signal kinetics were evaluated in the trachea and seven parenchymal Regions of Interest. Reference ranges for healthy subjects were defined for motion-corrected and uncorrected images.
RESULTS: Motion correction was successfully performed. Reference ranges were 0.11-1.21 seconds for tracheal transit time, 0-0.02 seconds for trachea-alveolar interval, 0.22-0.62 seconds for alveolar rise time and 0-76.6 arbitrary units for alveolar amplitude for motion corrected images, and 0-1.09 seconds, 0-0.11 seconds, 0.26-0.85 seconds, 46.4-99.8 arbitrary units for uncorrected images.
CONCLUSIONS: Evaluation of (3)He-distribution in the lung using motion correction of dynamic (3)He-ventilation imaging is feasible and gives more narrow reference ranges.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11882792     DOI: 10.1097/00004424-200203000-00005

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  5 in total

1.  (3)He-MRI in follow-up of lung transplant recipients.

Authors:  Klaus Kurt Gast; Julia Zaporozhan; Sebastian Ley; Alexander Biedermann; Frank Knitz; Balthasar Eberle; Joerg Schmiedeskamp; Claus-Peter Heussel; Eckhard Mayer; Wolfgang Günter Schreiber; Manfred Thelen; Hans-Ulrich Kauczor
Journal:  Eur Radiol       Date:  2003-10-16       Impact factor: 5.315

2.  Variation in time and space: what is the resolution?

Authors:  Gordon Drummond
Journal:  J Physiol       Date:  2007-08-09       Impact factor: 5.182

Review 3.  The role of advanced imaging techniques in cystic fibrosis follow-up: is there a place for MRI?

Authors:  Michael Puderbach; Monika Eichinger
Journal:  Pediatr Radiol       Date:  2010-04-30

Review 4.  [Functional 3He-MRI of the lungs].

Authors:  K K Gast; U Wolf
Journal:  Radiologe       Date:  2009-08       Impact factor: 0.635

Review 5.  New insights on COPD imaging via CT and MRI.

Authors:  N Sverzellati; F Molinari; T Pirronti; L Bonomo; P Spagnolo; M Zompatori
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2007
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.