Literature DB >> 11878683

Volume kinetics of glucose solutions given by intravenous infusion.

F Sjöstrand1, L Edsberg, R G Hahn.   

Abstract

Glucose solutions given by intravenous (i.v.) infusion exert volume effects that are governed by the amount of fluid administered and also by the metabolism of the glucose. To understand better how the body handles glucose solutions, two volume kinetic models were developed in which consideration was given to the osmotic fluid shifts that accompany the metabolism of glucose. These models were fitted to data obtained when 21 volunteers who were given approximately 1 litre of glucose 2.5 or 5% or Ringer's solution (control) over 45 min. The maximum haemodilution was similar for all three fluids, but it decreased more rapidly when glucose had been infused. The volume of distribution for the infused glucose molecules was larger (approximately 12 litres) than for the infused fluid, which amounted to (mean (SEM)) 3.7 (0.3) (glucose 2.5%), 2.8 (0.2) (glucose 5%), and 2.5 (0.2) litres (Ringer). Fluid accumulated in a remote (cellular) body fluid space when glucose had been administered (approximately 0.2 and 0.4 litres, respectively), while expansion of an intermediate fluid space (7.1 (1.3) litres) could be demonstrated in 33% of the Ringer experiments. In conclusion, kinetic models were developed which consider the relationship between the glucose metabolism and the disposition of intravenous fluid. One of them, in which infused fluid expands two instead of three body fluid spaces, was successfully fitted to data on blood glucose and blood haemoglobin obtained during infusions of 2.5 and 5% glucose.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11878683     DOI: 10.1093/bja/87.6.834

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  4 in total

1.  Oral nutrition or water loading before hip replacement surgery; a randomized clinical trial.

Authors:  Stefan Ljunggren; Robert G Hahn
Journal:  Trials       Date:  2012-07-02       Impact factor: 2.279

2.  Plasma volume expansion resulting from intravenous glucose tolerance test.

Authors:  Robert G Hahn; Thomas Nyström
Journal:  Comput Math Methods Med       Date:  2011-09-28       Impact factor: 2.238

Review 3.  The half-life of infusion fluids: An educational review.

Authors:  Robert G Hahn; Gordon Lyons
Journal:  Eur J Anaesthesiol       Date:  2016-07       Impact factor: 4.330

4.  Influence of the Dispersion Medium and Cryoprotectants on the Physico-Chemical Features of Gliadin- and Zein-Based Nanoparticles.

Authors:  Silvia Voci; Agnese Gagliardi; Maria Cristina Salvatici; Massimo Fresta; Donato Cosco
Journal:  Pharmaceutics       Date:  2022-01-30       Impact factor: 6.321

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.