The difference in pulse transit time to the toe and finger measured by photoplethysmography.

M Nitzan1, B Khanokh, Y Slovik.   

Abstract

Blood pressure pulse wave velocity (PWV) is a parameter which is related to arterial distensibility. Its direct assessment, by measuring the appearance time of a pressure pulse in two sites along an artery and the distance between the two sites, is complicated and inaccurate. In the current study, pulse transit time (PTT) to the toes and fingers of 44 normotensive male subjects was measured by photoplethysmography (PPG) and ECG. The arrival time of the pulses at the toe and finger was determined from the foot of the systolic rise of the PPG signal, i.e. at end-diastolic time. Two parameters, which are related to PWV, were tested: the time delay between the ECG R-wave and the arrival time of the pulses at the toe (E-T PTT), and the difference in the transit time of the blood pressure pulses between the toe and finger (T-F PTTD). E-T PTT and T-F PTTD decreased as functions of the subject's age and systolic blood pressure (SBP), but their dependence on the diastolic blood pressure (DBP) was not statistically significant. The decrease of the PTT parameters with age is attributed to the direct structural decrease of the arterial compliance with age and not to functional effects associated with the increase of the blood pressure with age, since the PTT parameters did not depend on DBP though the measurements were performed at end-diastole.

Entities:  

Mesh:

Year:  2002        PMID: 11876244     DOI: 10.1088/0967-3334/23/1/308

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  37 in total

1.  Baroreflex sensitivity assessment and heart rate variability: relation to maneuver and technique.

Authors:  S Carrasco-Sosa; M J Gaitán-González; R González-Camarena; Oscar Yáñez-Suárez
Journal:  Eur J Appl Physiol       Date:  2005-10-27       Impact factor: 3.078

2.  Pulse wave transit time for monitoring respiration rate.

Authors:  A Johansson; C Ahlstrom; T Lanne; P Ask
Journal:  Med Biol Eng Comput       Date:  2006-05-31       Impact factor: 2.602

3.  Asymmetric time-dependent model for the dynamic finger arterial pressure-volume relationship.

Authors:  Jaak Talts; Rein Raamat; Kersti Jagomägi
Journal:  Med Biol Eng Comput       Date:  2006-08-03       Impact factor: 2.602

4.  Factors that affect pulse wave time transmission in the monitoring of cardiovascular system.

Authors:  Jong Yong A Foo; Stephen J Wilson; Ping Wang
Journal:  J Clin Monit Comput       Date:  2008-03-19       Impact factor: 2.502

5.  Segmental blood flow and hemodynamic state of lymphedematous and nonlymphedematous arms.

Authors:  Leslie D Montgomery; Mary S Dietrich; Jane M Armer; B R Stewart; Sheila H Ridner
Journal:  Lymphat Res Biol       Date:  2011-03       Impact factor: 2.589

6.  DistancePPG: Robust non-contact vital signs monitoring using a camera.

Authors:  Mayank Kumar; Ashok Veeraraghavan; Ashutosh Sabharwal
Journal:  Biomed Opt Express       Date:  2015-04-06       Impact factor: 3.732

7.  Accurate measurement of the pulse wave delay with imaging photoplethysmography.

Authors:  Alexei A Kamshilin; Igor S Sidorov; Laura Babayan; Maxim A Volynsky; Rashid Giniatullin; Oleg V Mamontov
Journal:  Biomed Opt Express       Date:  2016-11-16       Impact factor: 3.732

Review 8.  Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging.

Authors:  Yu Sun; Nitish Thakor
Journal:  IEEE Trans Biomed Eng       Date:  2015-09-15       Impact factor: 4.538

Review 9.  Pulse transit time by R-wave-gated infrared photoplethysmography: review of the literature and personal experience.

Authors:  Jochanan E Naschitz; Stanislas Bezobchuk; Renata Mussafia-Priselac; Scott Sundick; Daniel Dreyfuss; Igal Khorshidi; Argyro Karidis; Hagit Manor; Mihael Nagar; Elisabeth Rubin Peck; Shannon Peck; Shimon Storch; Itzhak Rosner; Luis Gaitini
Journal:  J Clin Monit Comput       Date:  2004-12       Impact factor: 2.502

10.  Effects of continuous positive airway pressure and isocapnic-hypoxia on cerebral autoregulation in patients with obstructive sleep apnoea.

Authors:  Xavier Waltz; Andrew E Beaudin; Patrick J Hanly; Georgios D Mitsis; Marc J Poulin
Journal:  J Physiol       Date:  2016-12-01       Impact factor: 5.182

View more