Literature DB >> 11874009

Microleakage and penetration depth of three types of materials in fissure sealant: self-etching primer vs etching: an in vitro study.

D Gillet1, J Nancy, V Dupuis, G Dorignac.   

Abstract

Clinical preventive procedures must be done after a risk assessment. One of the risk factors is the occlusal morphology of the posterior teeth. These caries-free fissures must be sealed. This first in vitro experimentation of the study evaluated the microleakage and the penetration depth of three types of materials by Vivadent: Helioseal F, Tetric, Tetric Flow. The teeth were etched with phosphoric acid and bonded using a one bottle bonding in order to determine the best material for the sealing of the fissure. The depth of penetration of fuschine dye as well as that of the tested material was measured with a grid. The results, compared to the depth of the fissures, are expressed in percentage of penetration. The results were as follows: penetration of fuschine dye: 0% for the 2 composites, 100% for Helioseal F; penetration of the materials: 96.90% for Helioseal F, 70.82 for Tetric and 86.10 for Tetric Flow (significant difference, Wilcoxon test = 0.0105). In this first in vitro study, Tetric Flow shows no microleakage and is more efficient when compared to Helioseal F and Tetric in obturating deep fissures of non carious bicuspids. The second experiment of the study evaluated the microleakage and the penetration depth of Tetric Flow when it is bonded by two different methods: Group 1: total etch (phosphoric acid) and Scotch-bond 1 (3M), and Group 2: self-etching primer with Prompt (Espe). There was no significant difference (p > 0.03) between classical bonding vs self-etching primer. The self-etching primer Prompt is very efficient vs phosphoric acid in obturating the fissures of non carious bicuspids with Tetric Flow. It is concluded that for prevention by sealing, using a flowable ceromer (Tetric Flow) with the self-etching (Prompt), is a really good technique.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11874009     DOI: 10.17796/jcpd.26.2.31h2381422840n3n

Source DB:  PubMed          Journal:  J Clin Pediatr Dent        ISSN: 1053-4628            Impact factor:   1.065


  8 in total

1.  Clinical evaluation of three fissure sealants: 24 month follow-up.

Authors:  W Dukic; D Glavina
Journal:  Eur Arch Paediatr Dent       Date:  2007-09

2.  Microleakage of class-v composite restorations with different bonding systems on fluorosed teeth.

Authors:  Cigdem Küçükeşmen; Hayriye Sönmez
Journal:  Eur J Dent       Date:  2008-01

3.  In vitro comparison of microleakage of two materials used as pit and fissure sealants.

Authors:  Zahra Bahrololoomi; Aliasghar Soleymani; Zahra Heydari
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2011-09-05

4.  In Vitro Microleakage Comparison of Flowable Nanocomposites and Conventional Materials Used in Pit and Fissure Sealant Therapy.

Authors:  Sara Arastoo; Azam Behbudi; Vahid Rakhshan
Journal:  Front Dent       Date:  2019-01-20

5.  Evaluation of Marginal Microleakage and Depth of Penetration of Different Materials Used as Pit and Fissure Sealants: An In Vitro Study.

Authors:  Apra Butail; Parminder Dua; Ritu Mangla; Sheeba Saini; Ananya Chauhan; Swati Rana
Journal:  Int J Clin Pediatr Dent       Date:  2020 Jan-Feb

6.  A 12-month clinical evaluation of pit-and-fissure sealants placed with and without etch-and-rinse and self-etch adhesive systems in newly-erupted teeth.

Authors:  Maryam Karami Nogourani; Mohsen Janghorbani; Parvin Khadem; Zahra Jadidi; Shahriar Jalali
Journal:  J Appl Oral Sci       Date:  2012 May-Jun       Impact factor: 2.698

7.  Fissure sealant materials: Wear resistance of flowable composite resins.

Authors:  Sohrab Asefi; Solmaz Eskandarion; Shadi Hamidiaval
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2016-08-17

8.  Microleakage of pit and fissure sealings placed after enamel conditioning with phosphoric acid or with self-etching primers/adhesives.

Authors:  Stefanie Amend; Roland Frankenberger; Christina Boutsiouki; Vanessa Scharrelmann; Julia Winter; Norbert Krämer
Journal:  Clin Exp Dent Res       Date:  2021-04-07
  8 in total