Definition of a moving gross target volume for stereotactic radiation therapy of stented coronary arteries.

Edward M Leter1, Peter J C M Nowak, Koen Nieman, Pim J de Feyter, Stéphane G Carlier, Aristoteles Munne, Patrick W Serruys, Peter C Levendag.   

Abstract

PURPOSE: To measure the effect of cardiac motion on coronary artery stent position during the cardiac cycle as a first step toward exploring the feasibility of stereotactic external beam radiation therapy targeted at restenotic stented coronary arteries. METHODS AND MATERIALS: The three-dimensional (3D) position of eight coronary artery stents in 8 patients immobilized in a stereotactic body frame was studied noninvasively by single-breathhold ECG-gated multislice spiral computed tomography (MSCT) during 10 retrospectively selected phases, equally distributed throughout the R-R interval of consecutive cardiac cycles. The volume encompassing all measured 3D positions of the stent was measured.
RESULTS: Stent volumes measured by MSCT closely agreed with measurements by quantitative coronary angiography (r > 0.99). The mean of the maximum 3D stent center of mass displacement between any two phases during the cardiac cycle for all eight coronary arteries was 7.5 mm (range 3.3-20.5 mm) in the lateral direction, 8.6 mm (range 2.7-21.6 mm) in the ventrodorsal direction, and 8.2 mm (range 2.5-19.7 mm) in the craniocaudal direction. As was anticipated, the volume encompassing all measured 3D positions of the stent represented only a fraction of the whole heart volume in all patients, i.e., less than 0.6%.
CONCLUSIONS: ECG-gated MSCT allowed the measurement of the volume encompassing multiphase 3D positions of coronary artery stents during the cardiac cycle. This volume, a measure of the cardiac motion effect on coronary artery stent position during the cardiac cycle, represents a moving gross target for stereotactic external beam radiation therapy.

Entities:  

Mesh:

Year:  2002        PMID: 11872305     DOI: 10.1016/s0360-3016(01)02679-7

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  1 in total

1.  Estimation of the displacement of cardiac substructures and the motion of the coronary arteries using electrocardiographic gating.

Authors:  Wenyong Tan; Liying Xu; Xiaohong Wang; Dasheng Qiu; Guang Han; Desheng Hu
Journal:  Onco Targets Ther       Date:  2013-09-20       Impact factor: 4.147

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.