Literature DB >> 11872301

Imaging of 1.0-mm-diameter radiopaque markers with megavoltage X-rays: an improved online imaging system.

G Pang1, D J Beachey, P F O'Brien, J A Rowlands.   

Abstract

PURPOSE: To improve an online portal imaging system such that implanted cylindrical gold markers of small diameter (no more than 1.0 mm) can be visualized. These small markers would make the implantation procedure much less traumatic for the patient than the large markers (1.6 mm in diameter), which are usually used today to monitor prostate interfraction motion during radiation therapy. METHODS AND MATERIALS: Several changes have been made to a mirror-video based online imaging system to improve image quality. First, the conventional camera tube was replaced by an avalanche-multiplication-based video tube. This new camera tube has very high gain at the target such that the camera noise, which is one of the main causes of image degradation of online portal imaging systems, was overcome and effectively eliminated. Second, the conventional linear-accelerator (linac) target was replaced with a low atomic number (low-Z) target such that more diagnostic X-rays are present in the megavoltage X-ray beam. Third, the copper plate buildup layer for the phosphor screen was replaced by a thin plastic layer for detection of the diagnostic X-ray components in the beam generated by the low-Z target.
RESULTS: Radiopaque fiducial gold markers of different sizes, i.e., 1.0 mm (diameter) x 5 mm (length) and 0.8 mm (diameter) x 3 mm (length), embedded in an Alderson Rando phantom, can be clearly seen on the images acquired with our improved system. These markers could not be seen on images obtained with any commercial system available in our clinic.
CONCLUSION: This work demonstrates the visibility of small-diameter radiopaque markers with an improved online portal imaging system. These markers can be easily implanted into the prostate and used to monitor the interfraction motion of the prostate.

Entities:  

Mesh:

Year:  2002        PMID: 11872301     DOI: 10.1016/s0360-3016(01)02709-2

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  5 in total

1.  An MRI-compatible robotic system with hybrid tracking for MRI-guided prostate intervention.

Authors:  Axel Krieger; Iulian I Iordachita; Peter Guion; Anurag K Singh; Aradhana Kaushal; Cynthia Ménard; Peter A Pinto; Kevin Camphausen; Gabor Fichtinger; Louis L Whitcomb
Journal:  IEEE Trans Biomed Eng       Date:  2011-11       Impact factor: 4.538

2.  Design of a novel MRI compatible manipulator for image guided prostate interventions.

Authors:  Axel Krieger; Robert C Susil; Cynthia Ménard; Jonathan A Coleman; Gabor Fichtinger; Ergin Atalar; Louis L Whitcomb
Journal:  IEEE Trans Biomed Eng       Date:  2005-02       Impact factor: 4.538

3.  Displacements of fiducial markers in patients with prostate cancer treated with image guided radiotherapy: A single-institution descriptive study.

Authors:  Ricardo Cendales; Felipe Torres; Juan Arbelaez; Armando Gaitan; Jaider Vasquez; Ivan Bobadilla
Journal:  Rep Pract Oncol Radiother       Date:  2014-09-01

4.  Intra- and inter-radiation therapist reproducibility of daily isocenter verification using prostatic fiducial markers.

Authors:  Karen L Ullman; Holly Ning; Robert C Susil; Asna Ayele; Lucresse Jocelyn; Jan Havelos; Peter Guion; Huchen Xie; Guang Li; Barbara C Arora; Angela Cannon; Robert W Miller; C Norman Coleman; Kevin Camphausen; Cynthia Ménard
Journal:  Radiat Oncol       Date:  2006-02-28       Impact factor: 3.481

5.  Target localization for post-prostatectomy patients using CT and ultrasound image guidance.

Authors:  Kamen Paskalev; Steven Feigenberg; Rojymon Jacob; Shawn McNeeley; Eric Horwitz; Robert Price; Charlie Ma; Alan Pollack
Journal:  J Appl Clin Med Phys       Date:  2005-11-21       Impact factor: 2.102