Coupled microstrip line transverse electromagnetic resonator model for high-field magnetic resonance imaging.

G Bogdanov1, R Ludwig.   

Abstract

The performance modeling of RF resonators at high magnetic fields of 4.7 T and more requires a physical approach that goes beyond conventional lumped circuit concepts. The treatment of voltages and currents as variables in time and space leads to a coupled transmission line model, whereby the electric and magnetic fields are assumed static in planes orthogonal to the length of the resonator, but wave-like along its longitudinal axis. In this work a multiconductor transmission line (MTL) model is developed and successfully applied to analyze a 12-element unloaded and loaded microstrip line transverse electromagnetic (TEM) resonator coil for animal studies. The loading involves a homogeneous cylindrical dielectric insert of variable radius and length. This model formulation is capable of estimating the resonance spectrum, field distributions, and certain types of losses in the coil, while requiring only modest computational resources. The boundary element method is adopted to compute all relevant transmission line parameters needed to set up the transmission line matrices. Both the theoretical basis and its engineering implementation are discussed and the resulting model predictions are placed in context with measurements. A comparison between a conventional lumped circuit model and this distributed formulation is conducted, showing significant departures in the resonance response at higher frequencies. This MTL model is applied to simulate two small-bore animal systems: one of 7.5-cm inner diameter, tuned to 200 MHz (4.7 T for proton imaging), and one of 13.36-cm inner diameter, tuned to both 200 and 300 MHz (7 T). Copyright 2002 Wiley-Liss, Inc.

Mesh:

Year:  2002        PMID: 11870846     DOI: 10.1002/mrm.10083

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  2 in total

1.  Ultra-high-field RF coil development for evaluating upper extremity imaging applications.

Authors:  Shailesh B Raval; Tiejun Zhao; Narayanan Krishnamurthy; Tales Santini; Cynthia Britton; Vijay S Gorantla; Tamer S Ibrahim
Journal:  NMR Biomed       Date:  2016-11-03       Impact factor: 4.044

2.  Travelling-wave nuclear magnetic resonance.

Authors:  David O Brunner; Nicola De Zanche; Jürg Fröhlich; Jan Paska; Klaas P Pruessmann
Journal:  Nature       Date:  2009-02-19       Impact factor: 49.962

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.